6
Whisper H-80 Manual
Document #0022 REV B
SOUTHWEST WINDPOWER
2/4/2001
Installation
To
w
er
Wind Generator Model
H80-24
Battery System Volts
24
Minimum Amp x Hours
(20 hour rate)
200
Min. kwh (Volts x Amps x Hours/1000)
4
Tower height minimum: 7m (20 ft) above trees or obsta-
cles within 100m (300 ft).
100m (300 ft)
1. TOWER LOCATION/TYPE AND
HEIGHT. INSTALL TOWER
(Install tower following manufacturer’s instructions.)
Tower height minimum is 7 meters (20 feet) above trees or
obstacles within 100m (300ft). The lateral thrust rating at
top must match wind generator model. The highest point
on your property is generally best, but wind generator dis-
tance to battery and the battery voltage determine the cor-
rect wire size (Refer to wire size table pg. 5). A self sup-
porting tower occupies less ground area than a guyed tower
but is more expensive. A fold over design permits easy in-
stallation and maintenance on the ground and eliminates
the need for climbing.
Whisper Models H80 are suitable for roof or side-of-
building mounting on
unoccupied
buildings such as ga-
rage or barn. Some vibration transmission will be notice-
able from mounts to structure. Foundations must be de-
signed and approved for local wind/soil conditions.
1. INSTALLATION
DO THE FOLLOWING STEPS IN ORDER AND CIRCLE WHEN COMPLETE
Roof Mount
Side of Building Mount
H80
Mounting
Bracket
2.
PURCHASE BATTERIES OF PROPER SIZE.
Packages contains suggested battery size. See Table below
for minimum battery size.
MINIMUM BATTERY SIZES