14
Whisper H-80 Manual
Document #0022 REV B
SOUTHWEST WINDPOWER
2/4/2001
Maintenance
3. INSPECT THE TOWER
Follow all inspection and maintenance requirements of the
tower manufacturer. Tighten all nuts and bolts, especially
wire clips. Check for cracks and bent or broken parts at the
anchors and base structure. Check for broken strands and
tighten guys.
2. CHECK MECHANICAL CONDITION
WATCH AND LISTEN FROM THE TOWER BASE.
Use binoculars. There should be no mechanical noise,
rattle or vibration. The propeller and tail must not wobble.
Lower or climb the tower for inspection, if indicated. There
should be no buzzing either heard or felt with your hand on
the tower mast. Go to Electrical Problems, if indicated.
MAINTENANCE-
Monthly - H-80
Turbine
1. TEST BRAKE
(This checks electrical wiring.)
STOP THE WIND GENERATOR IN A MODERATE
WIND (CHARGING BUT NOT FURLING) No unusual
difficulty or noise should be experienced in stopping the
propeller. A noise during braking can indicate a
disconnected wire.
4. CHECK THE BATTERY
Add only distilled water if low.
Tighten battery connections
Remove corrosion and protect terminals
Wipe tops with baking soda solution.
EZ Wire