INSTALLATION & OPERATION MANUAL 1194659-ENGLISH, ELEC, REV 1 (11/21)
PAGE
30
OF 36
TruVection Electric Convection Ovens
Control Panel Access and Shut-Off Switch
To access the control panel components, remove the screw at the top of the control panel and pull the top of the control
panel out (see drawing below). A wiring diagram for the oven is located on the side of the control panel assembly. When
the control panel is slid out, all power to the control panel is cut off by a shut down switch that is located directly behind
and below the control panel. To re-energize the controls for troubleshooting, pull the white plunger on the shut down
switch forward.
Troubleshooting
Screw
Location of Wiring Diagram
Accessing Control Panel Components
FIGURE 17
Blower Wheel Replacement
To replace the blower wheel, do the following:
1. Remove racks and rack guides.
2. Remove rear air baffle in front of blower wheel.
3. Loosen the two square heads on blower wheel hub.
4. Pull blower wheel from motor shaft. If blower wheel is difficult to pull off, use puller disk (available from Southbend as
part number 1179100).
Wiring Diagrams
A wiring diagram is located on the side of the control panel assembly (as shown on page 30). Wiring diagrams also
appear on the following pages of this manual. Which wiring diagram is appropriate depends on the voltage.
Index of Wiring Diagrams
Page Number
Description
31
208/240 Volt Models
32
380 Volt Models
33
480 Volt Models
34
415 Volt WYE Models