Figure 19
High-Limit Thermostats Check
Continuity
1. Allow cavity bottom to cool before performing this test.
2.
DISCONNECT POWER AT CIRCUIT BREAKER.
3. Remove left side panel.
4. Disconnect wires from left and right terminals of each high-limit thermostat.
5. Test each high-limit thermostat for continuity (as shown above). There should be continuity when the
thermostat is cool. Replace as necessary.