SEZ S
ERIES
C
OUNTERTOP
S
TEAMERS
T
ROUBLESHOOTING
O
PERATOR
’
S
M
ANUAL
1183437
P
AGE
21
TROU
BLE
S
H
OOTI
N
G
Excessive Steam Coming from Pressure Relief Vent
Excessive steam coming from pressure relief vent.
DISCONNECT POWER AT CIRCUIT BREAKER.
Check pressure switch for proper operation (see Figure 17 on page 34).
Pressure switch OK?
No
Replace pressure switch.
Yes
Remove control panel, but leave plug connected.
Check controller (see Figure 15 on page 32).
Controller OK?
Check contactor and
replace as necessary
(see Figure 11 on page
28).
Yes
No
Replace controller.