TROUBLE SHOOTING:
Problem
Look for —
A. All ranges in battery will
— Main gas supply to ranges is "OFF."
not turn on
B. Counter model will not turn.
— Same as above.
A. All ranges produce excessive
—
Incorrect gas type supplied to battery.
carbon deposits
— Incorrect supply pressure.
B. Counter model produces
— Same as above.
excessive carbon deposit.
A. Only some ranges in a battery
— Incorrect orifices.
produce excessive carbon
— Primary air not adjusted properly.
deposits (burners)
B. Counter model produces
— Same as above.
excessive carbon deposits
(burners).
Only some pilots produce
— Pilot gas not adjusted properly.
excessive carbon deposits
— Incorrect pilot orifice.
Burner will
— Manual valve in "OFF" position.
not come on
— Pilot out.
— Clogged burner charge port.
Top section pilot will not
— Pilot gas not adjusted properly.
stay ignited
— Clogged orifice.
— Draft condition.
— Improper ventilation system.
— Air in gas line.
SERVICE
CHAR BROILERS
SECTION THREE — SERVICE
PAGE 2
Litho in U.S.A.
11-92