background image

NOD14: Floor Model High Efficiency Gas Pasta Cooker

  

TROUBLESHOOTING 

 

            L20-393, rev.0 (04/12) 

 

21 

Problem 

Probable Causes 

Corrective Actions 

Controller does not 
activate. 

No power to appliance. 

Check power cord and main 
building power supply. 

Circuit Breaker tripped. 

Reset circuit breaker. 

I/0 button not pressed On. 

Press I/0 button to to turn on 
controller. 

Controller not turned on. 

Turn on controller. 

Power Cord loose or not connected.  Connect power cord. 

Controller displays 
that it is heating but 
water will not heat. 

High temperature limit(s) has tripped

Allow appliance to cool and reset 
High temperature limit(s). 

4.4. TROUBLESHOOTING 

CHART 

 

4.5.  CONTROLLER WARNING DISPLAYS 

If your appliance is equipped with a temperature controller it may display the following warnings on its 
display. 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Display Problem 

Action 

 Water temperature 

is low. 

Wait for appliance to heat up. 

 Incorrect probe 

reading. 

Contact Authorized Service Company. 

 Water level is low. 

Turn off appliance.  Allow ample time for appliance to 
cool before filling with water and turning on. 

Incorrect probe 
reading. 

Contact Authorized Service Company. 

 Drain valve is open 

while controller is 
on. 

Turn off appliance.  Close drain valve before turning 
appliance back on. 

Summary of Contents for NOD14

Page 1: ...nual NOD14 Floor Model Gas Pasta Cooker NODR14 Floor Model Rinse Station Southbend A Middleby Corporation Company 1100 Old Honeycutt Road Fuquay Varina NC 27526 919 762 1000 phone 919 552 9798 fax D E...

Page 2: ...r safety Do not allow children to operate or play on or around the appliance WARNING If the appliance is equipped with a power cord and it is damaged it must be replaced by a Pitco Authorized Service...

Page 3: ...G INSTRUCTIONS 8 1 8 3 SELF CLEANING BURNER SYSTEM 9 1 8 4 PILOT FLAME ADJUSTMENT 9 1 8 5 MAIN BURNER SYSTEM ADJUSTMENT 10 1 9 INITIAL CLEANING 11 2 OPERATION 12 2 1 OPERATIONAL FEATURES 12 2 2 FILLIN...

Page 4: ...18 3 3 2 CONTROLLER 18 3 3 3 CONTROL BOX ELECTRICAL COMPONENTS 18 3 3 4 TANK 19 3 3 5 DRAIN SYSTEM 19 3 3 6 GAS COMBUSTION SYSTEM 19 3 4 VENTILATION HOOD 19 4 TROUBLESHOOTING 20 4 1 POWER FAILURE 20 4...

Page 5: ...per is only responsible for 15 days after delivery Check the packing list enclosed with your appliance to ensure that you have received all the parts to the appliance If you are missing any parts cont...

Page 6: ...minimum clearance requirements specified in this manual CAUTION To prevent equipment damage and or personal injury do not tilt the appliance onto any two of its casters or legs or pull the appliance b...

Page 7: ...rs 1 Remove all loose accessories and carefully place the appliance on its back to avoid damage to the cabinet and splash back Protect the outside of the appliance with cardboard or a drop cloth when...

Page 8: ...liance to reach operating temperature Prior to installation a water treatment specialist should inspect the water supply Water hardness should contain no more then 2 0 grains gallon The pH level shoul...

Page 9: ...ously at full demand The pressure at the gas valve must not exceed 1 2 PSI Each appliance is equipped to operate on one certain fuel type The type of fuel with which the appliance is intended to opera...

Page 10: ...This will prevent the appliance from being operated without the ventilator on If your appliance requires an electrical connection the power requirements are listed below 1 6 VENTILATION AND FIRE SAFET...

Page 11: ...the flue opening WARNING NEVER connect the ventilation blower or hood directly to the flue of this appliance The resulting increased flow of air through the combustion system will cause improper opera...

Page 12: ...til the water reaches the water level line approx 12 Gals 1 8 2 LIGHTING INSTRUCTIONS Refer to the following instructions to light the appliance 1 Open the shut off valve 2 for each cooking appliance...

Page 13: ...roampmeter between the Pilot flame sensor terminal 11 and the ignition wire Not Shown Observe proper polarity if the meter needle goes below 0 reverse the leads The current reading must be 1 0 A or gr...

Page 14: ...supply line installation which will cause poor performance of all appliances during peak usage The main gas supply pressure should only be checked by an authorized professional 3 The pressure reading...

Page 15: ...s on the food contact surfaces 1 9 INITIAL CLEANING When your appliance is shipped many of its parts may be covered with a thin coat of oil for protection Before the appliance is used for cooking it m...

Page 16: ...ng if the drain valve is opened 5 Drain Outlet Water exits the cook tank through the drain outlet when draining or overflowing 6 Overflow Line When the cook tank water level reaches the overflow water...

Page 17: ...NOD14 Floor Model High Efficiency Gas Pasta Cooker OPERATION L20 393 rev 0 04 12 13 FIGURE 3...

Page 18: ...ter will lower the pasta s internal temperature and stop the cooking process Rinsing or submerging will also prevent sticking and remove dissolved starch If the appliance is equipped with a rinse tank...

Page 19: ...ress the ON OFF 1 Button once The Digital Control will display in the display window To toggle between simmer and boil mode simply press the ON OFF 1 button to change modes 2 4 3 TIMER OPERATION Timer...

Page 20: ...reasing the quantity of water per pound or use of the manual fill option while cooking if equipped The manual fill should be set to a trickle while cooking to allow the water continue boiling When sto...

Page 21: ...around the appliance for loose parts or accessories that need to be secured or other foreign items ex Aerosol cans that should be removed from the area Check for water leaks around the drain lines an...

Page 22: ...of once a year by an Authorized Service Technician recommended by Pitco It may be necessary perform this inspection more then once a year 3 3 1 TEMPERATURE PROBE HIGH LIMIT PROBE Verify probes are in...

Page 23: ...Check for gas leaks Check and clean vent tube on gas valve pressure regulator Check burners clean debris and grease from pilot and pilot orifice tips Check and adjust burner manifold gas pressure to...

Page 24: ...itch 1 Turn the appliance off 2 Allow the appliance ample time to cool to room temperature 3 Add water to the cook tank as needed 4 Press the high limit reset button 7 See Figure 3 5 The high limit sw...

Page 25: ...heat High temperature limit s has tripped Allow appliance to cool and reset High temperature limit s 4 4 TROUBLESHOOTING CHART 4 5 CONTROLLER WARNING DISPLAYS If your appliance is equipped with a tem...

Page 26: ...L20 393 rev 0 04 12...

Page 27: ...L20 331 rev 02 08 11...

Page 28: ...L20 393 rev 0 04 12 Southbend A Middleby Corporation Company 1100 Old Honeycutt Road Fuquay Varina NC 27526 919 762 1000 phone 919 552 9798 fax...

Reviews: