NOD14: Floor Model High Efficiency Gas Pasta Cooker
TROUBLESHOOTING
L20-393, rev.0 (04/12)
21
Problem
Probable Causes
Corrective Actions
Controller does not
activate.
No power to appliance.
Check power cord and main
building power supply.
Circuit Breaker tripped.
Reset circuit breaker.
I/0 button not pressed On.
Press I/0 button to to turn on
controller.
Controller not turned on.
Turn on controller.
Power Cord loose or not connected. Connect power cord.
Controller displays
that it is heating but
water will not heat.
High temperature limit(s) has tripped
Allow appliance to cool and reset
High temperature limit(s).
4.4. TROUBLESHOOTING
CHART
4.5. CONTROLLER WARNING DISPLAYS
If your appliance is equipped with a temperature controller it may display the following warnings on its
display.
Display Problem
Action
Water temperature
is low.
Wait for appliance to heat up.
Incorrect probe
reading.
Contact Authorized Service Company.
Water level is low.
Turn off appliance. Allow ample time for appliance to
cool before filling with water and turning on.
Incorrect probe
reading.
Contact Authorized Service Company.
Drain valve is open
while controller is
on.
Turn off appliance. Close drain valve before turning