NOD14: Floor Model High Efficiency Gas Pasta Cooker
INSTALLATION
L20-393, rev.0 (04/12)
7
WARNING
Ensure that your ventilation system does not cause a down draft at the appliance’s flue
opening. A down draft will not allow the appliance to exhaust properly and will cause
overheating, which may cause permanent damage. Damage caused by down drafts will not
be covered by the warranty. NEVER allow anything to obstruct the flow of combustion air or
ventilation air entering or exiting the appliance. NEVER place anything on top of the flue
exhaust area, or block the flue in any way. Never place a hood grease condensating drip
pan over the flue opening.
WARNING
NEVER connect the ventilation blower or hood directly to the flue of this appliance. The
resulting increased flow of air through the combustion system will cause improper
operation, poor temperature recovery, poor ignition and could extinguish the pilot.
1.7. INSPECTION
Before you begin filling and adjusting the appliance, perform the following visual checks:
After the appliance is in its permanent location, check the levelness. Any additional leveling that is necessary
can be performed as previously described.
Ensure that the temperature probe (2), and high temperature limit sensing bulb (1) is in place and secure.
Check the high limit bulb mounting wing nut(s) (3) to ensure that they are tight.
Review the installation portion of this manual and ensure that all steps have been followed and executed
properly.