4
OR
OR
WITH
Receptacle
Plug
UTS MPO Serie
s
|
BT319
The following tools and materials are necessary for preparation, assembly, inspection, and maintenance of the connector and cable assembly.
Follow the tool instruction for operation and safety guidelines.
Tools
•
Cable jacket strip tool
•
Aramid Fiber Shears
•
Fiber Stripping Tool
•
15 mm U–wrench
•
28 mm U–wrench
•
36.5 mm U–wrench
•
Nipper (Oeticker Standard)
•
Heat gun (optional)
Material
•
MPO contact: the UTS MPO connector range
can adapt all kind of MPO contact as defined
per IEC 61754-20
•
Cable: the UTS MPO connector range can
adapt all type of standard cable from 3 to
6mm outer diameter.
•
Above these diameter limits some
adaptations are necessary
•
Suggested glue: LOCTITE
®
480 PRISM
Instant Adhesive
Assembly instructions
The assembly should be done in a dust free
and dried environment, in accordance with
fiber optics good practices.
Make sure that all components are free from
contamination.
The assembly instruction is only a guideline
and the assembly/manipulations are under the
responsibility of the assembler. Any change of
product or material is under the responsibility
of the assembler.
Tool & Material
Accessories
Sealing caps
Part number
UTS618DCG2
Part number
UTS18DCG2
For UTS1JC18MPN & UTS718MPN
For UTS6JC18MPN
Connector type
Backshell
Part number
Male insert
Female insert
Free hanging receptacle
Cable gland
UTS1JC18MPN
-
Plug
Cable gland
-
UTS6JC18MPN
Jam nut receptacle
Without
UTS718MPN
-
Connector part numbers
Summary of Contents for UTS MPO Series