For a managed device that bypasses with a crossover connection, wire the device
as would normally be done without a device deployed. The link should work with
power to the device removed. In most cases you should use two straight-through
cables to connect the device to the two endpoints.
Crossover Bypass Connection Cabling
The
Valid Configurations for Hardware Bypass
and table indicates where you
should use crossover or straight-through cables in your hardware bypass
configurations. Note that a Layer 2 port functions as a straight-through (MDI)
endpoint in the deployment, and a Layer 3 port functions as a crossover (MDIX)
endpoint in the deployment. The total crossovers (cables and appliances) should
be an odd number for bypass to function properly.