background image

IMPORTANT SAFETY SYMBOLS

The symbol is used to indicate that some hazardous live terminals are 

involved within this apparatus, even under the normal operating con-

ditions, which may be sufficient to constitute the risk of electric shock 

or death.
The symbol is used in the service documentation to indicate that spe-

cific component shall be replaced only by the component specified in 

that documentation for safety reasons.

Protective grounding terminal
Alternating current/voltage
Hazardous live terminal
Denotes the apparatus is turned on
Denotes the apparatus is turned off

WARNING:

Describes precautions that should be observed to prevent the danger 

of injury or death to the operator.

CAUTION:

Describes precautions that should be observed to prevent danger of 

the apparatus.
To protect the environment, please try to recycle the packing material 

as much as possible
Don’t throw this product away just as general trash, please deal with 

the product follow the abandon electronic product regulation in your 

country.

TAKING CARE OF YOUR PRODUCT

 

f

Read these instructions

 

f

Keep these instructions

 

f

Follow all instructions

Water / Moisture

The apparatus should be protected from moisture and rain and can not be used near 

water; for example near a bathtub, a kitchen sink, a swimming pool, etc.

Heat

The apparatus should be located away from heat sources such as radiators, stoves or 

4

ENGLISH

PAR-18-18W-IP65 User manual

Summary of Contents for PAR-18-18W-IP65

Page 1: ...Please read this manual carefully and proper take care of this manual USER MANUAL PAR 18 18W IP65 18x18W RGBW A UV 6in1 LED PAR Light for Outdoor use IP65 ...

Page 2: ...em and if you want to collaborate we are looking for a feedback from you about the operation of the product and possible im provements to introduce in the next future Go to our website www soundsationmusic com and send an e mail with your opinion this will help us to build instruments ever closer to customer s real requirements One last thing read this manual before using the instrument an incorre...

Page 3: ... MAIN FEATURES 6 4 OVERHEAD RIGGING 7 5 MAINS CONNECTIONS 7 6 DMX CONNECTION 7 6 1 DMX Terminator 8 6 2 3 Pin vs 5 Pin DMX cables 9 7 FRONT PANEL 9 8 MENU INSTRUCTION 10 9 OPERATION MODES 10 10 DMX Channel Chart 11 11 SPECIFICATIONS 13 12 WARRANTY AND SERVICE 14 13 WARNING 14 3 ENGLISH ...

Page 4: ...at should be observed to prevent the danger of injury or death to the operator CAUTION Describes precautions that should be observed to prevent danger of the apparatus To protect the environment please try to recycle the packing material as much as possible Don t throw this product away just as general trash please deal with the product follow the abandon electronic product regulation in your coun...

Page 5: ...nd cleaning the unit Improper electrical wiring may invalidate the product warranty To avoid electric shock all fixtures must be connected to circuits with a suitable ground Do not power on and power off the fixture in a short time DMX connection When use DMX controller please make sure that there is no interference sources e g intercom high frequency radio waves and radiation source Cleaning Clea...

Page 6: ...NDSATION dealer or check out our website www soundsationmusic com for any accessories you could need to ensure best performance of the product 2 OVERVIEW Especially designed for outdoor use thanks to the IP65 protection degree SOUNDSA TION PAR 18 18W IP65 is the right choice for architectural applications when a power ful 18 x 18W projector is required It offers a complete color palette thanks to ...

Page 7: ...well fixed a free swinging mounting is dangerous and may not be considered Before the first time use it must be inspected by professional staff to make sure safety inspection regularly every year 5 MAINS CONNECTIONS Connect the device to the mains with the supplied power cable Please note that power voltage and frequency are the same as the marked voltage and frequency of device when connecting po...

Page 8: ...ent communication protocol however errors still occasionally occur In order to prevent electrical noise from disturbing and corrupting the DMX control signals a good habit is to connect DMX output of last fixture in the chain to a DMX terminator especially over long signal cable runs 120ohm 1 4W resistor DMX Terminator The DMX terminator is simply an XLR connector with a 120Ω ohm 1 4 Watt resistor...

Page 9: ...g and socket stan dards 5 Pins XLR plug Pin 1 GND Screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 Pins XLR socket Pin 1 GND Screen Pin 2 Signal Pin 3 Signal 5 Pins XLR socket Pin 1 GND Screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 Pins XLR plug Pin 1 GND Screen Pin 2 Signal Pin 3 Signal 7 FRONT PANEL POWER out POWER in 100 240v 50 60H z DMX OUT DMX IN PAR 18 18W IP65 enter MENU 2 4...

Page 10: ... Color jump speed from slow to fast EE01 EE01 EE99 Slow off quick on speed from slow to fast FF01 FF01 FF99 Color fade speed from slow to fast ST01 ST01 ST32 SP01 SP99 1 32 kinds of strobe effect Speed from slow to fast SOU1 SE01 SE99 SOU2 SE01 SE99 SOU3 SE01 SE99 SOU1 led changeable effect SOU2 strobe effect SOU3 Lightning strobe effect R255 R000 R255 Red Dimmer 0 100 G255 R000 R255 Green Dimmer ...

Page 11: ...el Chart 6CH Mode d001 Channel Value Description CH1 000 255 Red Dimmer 0 100 CH2 000 255 Green Dimmer 0 100 CH3 000 255 Blue Dimmer 0 100 CH4 000 255 White Dimmer 0 100 CH5 000 255 Amber Dimmer 0 100 CH6 000 255 Ultra Violet Dimmer 0 100 10CH 1 A001 Channel Value Description CH1 000 255 Linear dimmer 0 100 CH2 000 255 Red Dimmer 0 100 CH3 000 255 Green Dimmer 0 100 CH4 000 255 Blue Dimmer 0 100 C...

Page 12: ...n 000 009 No function 010 050 Static color 051 100 LED jump 101 150 Slow off quick on 151 200 Led fade 201 255 Sound active CH4 Color change Speed adjustment Works with CH3 000 255 When CH3 010 050 pushes CH4 to a static color selection When CH9 051 200 pushes CH4 for the additional speed Speed changes from slow to fast CH5 000 255 Red Dimmer 0 100 CH6 000 255 Green Dimmer 0 100 CH7 000 255 Blue D...

Page 13: ...ux RGBWA UV 30000 Lux DMX Channel Modes 6CH 10CH 1 10CH 2 Maximum External Temp 104 F 40 C Cooling System Convection No Fan Power Supply Type Switching internal Range 100 240V 50 60Hz Consumption 230W Light Size LxHxD 260x310x250 mm bracket installed Light Weight 4 kg Packing Size LxHxD 290x290x340 mm Packing Weight 4 5 kg 13 ENGLISH PAR 18 18W IP65 pro User manual ...

Page 14: ...i 10 62017 Porto Recanati Italy In order to send a product to service center you need an RMA number Shipping charges have to be covered by the owner of the prod uct For further information please visit www soundsationmusic com 13 W ARNING PLEASE READ CAREFULLY EU and EEA Norway Iceland and Liechtenstein only This symbol indicates that this product is not to be disposed of with your household waste...

Page 15: ...viene importato nella UE da FRENEXPORT SPA Via Enzo Ferrari 10 62017 Porto Recanati Italy www soundsa tionmusic com Soundsation is a registered trademark of FRENEXPORT SPA Italy Soundsation è un marchio di fabbrica registrato della FRENEXPORT SPA Italy ...

Page 16: ...www soundsa tionmusic com Ver 1 0 July 2017 ...