DMX Connection Schematic Diagram
DMX 512 Connection / Connection between Fixtures
The wires must not come into contact with each other; otherwise the
fixtures will not work at all, or will not work properly.
0nly use a shielded signal cable and 3-pin / 5-pin XLR-plugs and connectors
so that the device can connect with the controller or connect one fixture
with others.
9
DMX Channels
16 DMX Channels Description:
Channel
Function
Data
Function Description
CH1
Color Wheel
0--4
White
5--8
White, red
9--13
Red
14--17
Red, yellow
18--22
Yellow
23--26
Yellow, blue
27--30
Blue
31--35
Blue, green
36--39
Green
40--44
Green, deep yellow
45--48
Deep yellow
49--53
Deep yellow, magenta
54--57
Magenta
58--61
Magenta, UV
62--66
UV
67--70
UV, CTO
71--75
CTO
76--79
CTO, yellow green
80--83
Yellow green
84--88
Yellow green, brown yellow
89--92
Brown yellow
93--97
Brown yellow, cyan
98--101
Cyan
14