IAPA Connection Details:
(refer to Diagram 3 on page 11)
• Line In:
Balanced line level input terminals for connection of up to
fi
ve remote Outreach Input plates (APA/APL, etc).
• Mic Rcvr In:
Unbalanced microphone level input terminals for connection of a Chiayo IWR-220 infrared wireless
microphone receiver. It is also possible to use this input to connect Chiayo RF radio microphone receivers.
Contact CIE-Group Technical Support (0115 977 0075) for advice.
• 18v DC Out (Line Level / Line Sig Out):
18v DC supply terminals providing power to the Outreach plates. These terminals will provide a combined
maximum output current of 100mA.
• 15v DC Out: (Mic Rcvr)
15v DC supply terminals providing power to the IWR-220 receiver only. These terminals will provide a combined
maximum output current of 500mA.
• Line Output:
Balanced line level output terminals available on the IAPA for connection to the line level input of other equipment
such as the APA/LLO Outreach plate or Induction Loop ampli
fi
ers. These can be used for connecting multiple
i-ceilings panels in larger rooms where one speaker would not give suf
fi
cient sound coverage.
• Ext Spkr:
External 8 ohm speaker terminals for powering a single additional Armstrong CS1000 or Pro series panel. Note:
damage to the ampli
fi
er will occur if speakers with a total impedance of less than 8 ohms are connected to these
terminals.
• Mains In:
The mains input should be connected using an IEC type connector. The supply input should be 230V AC
(±10%) 50Hz.
10
IAPA Connection Details
Warning
No connections should be made to the unit whilst the mains power is connected