![SoundDigital 1000.1 EVOX2 Owner'S Manual Download Page 12](http://html.mh-extra.com/html/sounddigital/1000-1-evox2/1000-1-evox2_owners-manual_1334307012.webp)
SD RLC / GAIN SETTING
Necessary equipament:
Ø
Digital AC voltmeter;
Ø
Media with sine wave test tone
60Hz recorded at 0db;
Ø
Screwdriver 1/8" ( for gain set);
Set up procedure:
Turn the gain control all the way
Ø
down;
Ø
Disconnect the output cables from
the amplifier outputs;
Ø
Turn off all processing (bass, treble,
loudness, EQ, etc.);
Ø
Set the source unit volume to 3/4 of
full volume;
Ø
Set the source unit's fader control
to center position;
Ø
Set the variable "LOW PASS"
c r o s s o v e r i n 5 0 0 H z a n d t h e
"SUBSONIC" in 5Hz;
Ø
Use a 60 Hz sine wave;
Ø
Increase the gain control until the
"CLIP" LED starts blinking;
Ø
Return the gain to the limit where
the "CLIP" LED stops blinking and
remains off;
Ø
Once you have adjusted the
amplifier to the correct voltage
output, turn off the source unit and
reconnect the speaker(s).
EXTERNAL LEVEL CONTROL - SD RLC (*Not included)
GAIN SETTING
The SD RLC is an easy-to-install external level
control accessory that allows you to tune the
level of SOUNDIGITAL amplifiers that have
remote level control.
In SD RLC, you can adjust the amplifier level
without having to lean over and adjust the gain
setting on the amplifier and can monitor the
“CLIP” LED which is also available on the
accessory.