![Sorel SBMC Installation And Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/sorel/sbmc/sbmc_installation-and-operating-instructions-manual_1332657018.webp)
Offset ∆T
Correction factor for the temperature difference for heat metering
Since the collector temperature and the storage temperature can be used for the heat quantity metering, depending on the sys-
tem, there may be deviations from the displayed collected temperature to the actual previous temperature or the displayed stor-
age temperature to the actual return temperature. This deviation can be corrected with the adjustment value Offset ΔT
Example: displayed collector temperature 40°C, read previous temperature 39°C, displayed storage temperature 30°C, read
return temperature 31° means a setting of -20% (displayed ∆T 10K, actual ∆T 8K => -20% correction value)
Daylight saving time
If this function is activated, the controller automatically changes to winter time or summer time (DST, Daylight Savings Time).
8. Menu Lock
Secure the controller against unintentional changing and compromise of
basic functions.
The menus listed below remain completely accessible despite the menu
lock being activated, and can be used to make adjustments if necessary:
1. Measurement values
2. Statistics
3. Times
8. Menu lock
9. Service values
9. Service values
Serve for remote diagnosis by a specialist or the manufacturer in the event
of errors, etc.
Enter the values into the table when an error occurs.
10. Language
To select the menu language. For initial commissioning the query is auto-
matic.
18