Declaration of Conformity

For ATEX/IECEx Certified Models

 

 

 

R Series Pressure Switches

SOR Inc.

14685 West 105

th

 Street

Lenexa, Kansas 66215-2003

United States of America

 

June 18, 2020

ATEX Directive (2014/34/EU) Equipment Intended for use 

in Potentially Explosive Atmospheres 

EN 60079-0:2012 + A11:2013   IEC 60079-0:2011

EN 60079-11:2012  

IEC 60079-11:2011

        

II 2 G Ex ia IIC T6...T4 Gb

            T6 

(-40°C

Ta 

+75°C)

 

            T5 

(-40°C

Ta 

+90°C) 

            T4 

(-40°C

Ta 

+125°C)

 

EC-Type Examination Certificate

Baseefa11ATEX0125 

Issued February 16, 2012

IECEx BAS 15.0150 

Issued April 19, 2016

SGS Fimko Oy

  (Notified Body No. 0598)

Takomotie 8
Helsinki, 00380

Finland

Michael J. Bequette (VP of Engineering)

Form 1539 (06.20) SOR Inc. 

Product

Manufacturer

Place of Issue

Date of Issue

We declare under our sole 

responsibility that the 

above products conform to 

the following specifications 

and directives

Carries the marking

Reference document

  

ATEX Notified Body

Person responsible

EU Declaration 

            of Conformity

 

14685 West 105th Street, Lenexa, KS 66215-2003

913-888-2630 • 800-676-6794 USA • 913-888-0767 FAX

Engineered to Order with Off-the-Shelf Speed

Michael J. Bequette

Summary of Contents for GI169

Page 1: ...ocess temperatures The instrument s behavior is determined by vapor pressure 105 range model fill media is inert gas NOTE If you suspect that a product is defective contact the factory or the SOR Repr...

Page 2: ...6 35 mm bolts o Mounting by electrical conduit connection is NOT recommended p Suggested mounting orientation is electrical conduit connection at 3 or 9 o clock and sensing body at 6 o clock However t...

Page 3: ...A thermowell filled with thermal transfer media reduces lag Safety Integrity Level SIL Installation Requirements The SOR pressure switches have been evaluated as Type A safety related hardware To meet...

Page 4: ...movement or replacement in the field will degrade performance and could render the device inoperative unless factory authorized procedures are followed Housing Type Conduit Connection Contact Termina...

Page 5: ...Use 3 4 inch open end wrench to turn hex adjusting nut clockwise in to increase set point and counterclockwise out to decrease set point Approximate set point can be obtained by sighting across top of...

Page 6: ...r all Others 263 4 Max 10 37 308 3 12 06 Approximate Range of Adjustment Remote Mount Probe Dimensions Linear mm inches Drawings are for reference only Contact the factory for certified drawings for a...

Page 7: ...25 mm 107 2 112 0 112 0 112 0 112 0 in 4 22 4 41 4 41 4 41 4 41 C 235 125 115 mm 128 3 135 to 396 147 to 409 185 to 447 216 to 480 in 5 05 5 3 to 15 6 5 8 to 16 1 7 3 to 17 6 8 5 to 18 9 105 mm 170 to...

Page 8: ...f clause 6 3 12 EN 60079 11 2007 The unit is capable of withstanding a 500 Vrms isolation test between circuit and enclosure ATEX IECEx Marking Information For Mini Hermet ATEX IEXEx Certified Models...

Page 9: ...for use in Potentially Explosive Atmospheres EN 60079 0 2012 A11 2013 IEC 60079 0 2011 EN 60079 1 2014 IEC 60079 1 2014 06 II 2 G Ex db IIC T6 T5 Gb T6 40 C Ta 60 C T5 40 C Ta 75 C EC Type Examination...

Page 10: ...amination Certi cate Baseefa11ATEX0125 Issued February 16 2012 IECEx BAS 15 0150 Issued April 19 2016 SGS Fimko Oy Noti ed Body No 0598 Takomotie 8 Helsinki 00380 Finland Michael J Bequette VP of Engi...

Page 11: ...Form 169 07 21 SOR Inc 11 12...

Page 12: ...12 12 Form 169 07 21 SOR Inc 14685 W 105th St Lenexa KS 66215 913 888 2630 800 676 6794 USA SORInc Registered Quality System to ISO 9001...

Reviews: