7. Turn the JOG dial to display “LDPWR CHECK”.
8. Press the YES/ENTER button once to display “LD 0.9mW
$
”. Check that the reading of the laser power meter become
0.85 to 0.91 mW.
9. Press the YES/ENTER button once more to display “LD 7.0
mW $
”. Check that the reading the laser power meter and
digital voltmeter satisfy the specified value.
Note down the digital voltmeter reading value.
6-4. Self-Recording/playback Check
Prepare a continuous recording disc using the unit to be repaired
and check the error rate.
Checking Procedure:
1. Load a recordable disc (blank disc).
2. Turn the JOG dial to display “CREC MODE”.
3. Press the YES/ENTER button to display “CREC MID”.
4. When recording starts, lights up “ REC ” and display “CREC
(@@@@)” (@@@@ is the address).
5. About 1 minute later, press the NO/CANCEL button to
stop continuous recording.
6. Turn the JOG dial to display “CPLAY MODE”.
7. Press the YES/ENTER button to display “CPLAY MID”.
8. “C1 =
AD =
” will be displayed.
9. Check that the C1 error becomes below 80 and the ADER be-
low 2.
10.Press the NO/CANCEL button to stop play back, then press
the
Z
(MD) button and take out the disc.
Note:
After the TEST MODE is entered, insert the disc.
7. TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25
°
C reference data.
Note:
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22
°
C to
28
°
C.
Perform it immediately after the power is turned on when the
internal temperature of the unit is the same as the ambient tem
perature of 22
°
C to 28
°
C.
3. When D501 has been replaced, perform this adjustment after
the tem-perature of this part has become the ambient tempera
ture.
Adjusting Procedure:
1. Turn the JOG dial to display “TEMP ADJUST”.
2. Press the YES/ENTER button to select the “TEMP ADJUST”
mode.
3. “TEMP =
” and the current temperature data will be displayed.
4. To save the data, press the YES/ENTER button.
When not saving the data, press the NO/CANCEL button.
5. When the YES/ENTER button is pressed, “TEMP = SAVE”
will be displayed and turned back to “TEMP ADJUST” display
then. When the NO/CANCEL button is pressed, “TEMP
ADJUST” will be displayed immediately.
Specified Value:
The “TEMP =
” should be within “E0 - EF”, “F0 - FF”, “00 -
0F”,“10 - 1F” and “20 - 2F”.
Adjusting Procedure:
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
m
but-ton
or
M
button to move the optical pick-up)
Connect the digital voltmeter to TP502 (I+3 V) and TP503
(IOP) on the MD board.
2. Turn the JOG dial to display “LDPWR ADJUST”.
(Laser power: For adjustment)
3. Press the YES/ENTER button once to display “LD 0.9 mW
$
”.
4. Turn the JOG dial so that the reading of the laser power meter
becomes 0.85 to 0.91 mW. Press the YES/ENTER button after
setting the range knob of the laser power meter, and save the
adjustment results. (“LD SAVE $
” will be displayed for a
moment)
5. Then “LD 7.0 mW $
” will be displayed.
6. Turn the JOG dial and adjust so that the reading on the laser
power meter is 6.9 to 7.1 mW. Press the YES/ENTER button to
save the setting.
Note:
Do not perform the emission with 7.0 mW more than 15 sec
onds continuously.
8. LASER POWER ADJUSTMENT
Connection:
laser
power meter
Optical pick-up
objective lens
R622
C508
C521
C512
L503
C502
R511
C518
C511
C505
R505
R510
Q503
R508
R513
R509
R517
C519
C517
C520 C522
R519
R516
R512
C506
R504
R503
Q506
Q507
Q505
Q504
R518
Q502
R515
IC502
R5
2
L501
L506
C611
R633
Q501
R514
R502
C607
TP503
(IOP)
TP502
(I+3V)
(TE)
1
36
25
24
13
15
20
37
48
45
40
30
35
5
1012
TP502 (I+3V)
TP503 (IOP)
MD BOARD
(SIDE B)
digital voltmeter