29
1.3 No Power DDCON / LDO
Please Refer page 24 -25 for Ref No.
DDCONs & LDOs Check
Check Enable pin
voltage
Is voltage >3V?
1.2 No Power U-Com Failure
or
Enable source
no
START
yes
Change DDCON
Or LDO IC
Check Vcc voltage
C4xx/C8xx
Is voltage >3V?
Check 3.3V_STBY (Power board)
no
yes
yes
Board
Operation
IC Ref
Voltage supply
BM5S21
DC/DC
IC418
5.0V_STBY_H
BM5S21
LDO
IC403
3.3V_MAIN_H
BM5S21
LDO
IC806
1.8V_M5_ET_STBY
BM5S21
LDO
IC809
3.3V_M5_STBY
T R O U B L E S H O O T I N G
SAFETY NOTES
SELF DIAGNOSTIC FUNCTION
TROUBLESHOOTING
SERVICE ADJUSTMENT
DIAGRAM
HANDLING GUIDE
29
SYS SET