16
Self Diagnosis Display
;
SELF CHECK
<<
002 MAIN POWER 000000000000 000000000000 000000000000 000
003 DC ALERT 000000000000 000000000000 000000000000 000
003 AUD ERR 150101000018 150101000018 150101000018 003
003 AUD ERR I2C 150101000218 150101000223 150101000105 003
003 TU DEMOD I2C 000000000000 000000000000 000000000000 000
003 AMB ERR I2C 000000000000 000000000000 000000000000 000
004 LD ERR 000000000000 000000000000 000000000000 000
004 BCM ERR 000000000000 000000000000 000000000000 000
005 TCON ERR 150101000504 000000000000 000000000000 001
005 P ID ERR 000000000000 000000000000 000000000000 000
006 BACKLIGHT ERR 000000000000 000000000000 000000000000 000
007 TEMP ERR 150101000200 150101000002 000000000000 002
007 TEMP ERR I2C 000000000000 000000000000 000000000000 000
008 4KBE ERR 000000000000 000000000000 000000000000 000
Back
00005 00414 00002
[Home]Exit [Up/Down]Scroll
Smart Core Red LED
blinking count
Error Item
Error count
Total Operation Time [hr] – Boot Count – Panel Operation Time [hr]
Error
timestamp
for last
recorded
error
Error
timestamp
for 2nd last
recorded
error
Error
timestamp
for 3rd last
recorded
error
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
Panel Operation Time clear
<7> -> <0>
Timestamps and Error Count clear
<8> -> <0>
Total Operation Time and Boot Count clear
<9> -> <0>
•Panel Operation Time is recorded every
30 min, but Total Operation Time is recorded
every 1 hour. Therefore, the panel op. time
might become larger than the total op. time.
S E L F D I A G N O S T I C F U N C T I O N
SAFETY NOTES
SELF DIAGNOSTIC FUNCTION
TROUBLESHOOTING
SERVICE ADJUSTMENT
DIAGRAM
HANDLING GUIDE
16
SYS SET
2021/02/04 23:38:48 (GMT+09:00)