background image

PDW-HD1500 IM

1 (P)

Vorsicht!

Explosionsgefahr bei unsachgemäßem Austausch

der Batterie.

Ersatz nur durch denselben oder einen vom

Hersteller empfohlenen ähnlichen Typ. Entsorgung

gebrauchter Batterien nach Angaben des

Herstellers.

ATTENTION

Il y a danger d’explosion s’il y a remplacement

incorrect de la batterie.

Remplacer uniquement avec une batterie du même

type ou d’un type équivalent recommandé par le

constructeur.

Mettre au rebut les batteries usagées conformément

aux instructions du fabricant.

ADVARSEL!

Lithiumbatteri-Eksplosionsfare ved fejlagtig

håndtering.

Udskiftning må kun ske med batteri

af samme fabrikat og type.

Levér det brugte batteri tilbage til leverandøren.

ADVARSEL

Lithiumbatteri - Eksplosjonsfare.

Ved utskifting benyttes kun batteri som

anbefalt av apparatfabrikanten.

Brukt batteri returneres

apparatleverandøren.

VARNING

Explosionsfara vid felaktigt batteribyte.

Använd samma batterityp eller en likvärdig typ

som rekommenderas av apparattillverkaren.

Kassera använt batteri enligt gällande

föreskrifter.

VAROITUS

Paristo voi räjähtää jos se on virheellisesti

asennettu.

Vaihda paristo ainoastaan laitevalmistajan

suosittelemaan tyyppiin.

Hävitä käytetty paristo valmistajan ohjeiden

mukaisesti.

CAUTION

Danger of explosion if battery is incorrectly replaced.

Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’s instructions.

Summary of Contents for XDCAM PDW-HD1500

Page 1: ...PROFESSIONAL DISC RECORDER PDW HD1500 INSTALLATION MANUAL 1st Edition ...

Page 2: ... bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparat...

Page 3: ...brikat og type Levér det brugte batteri tilbage til leverandøren ADVARSEL Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleverandøren VARNING Explosionsfara vid felaktigt batteribyte Använd samma batterityp eller en likvärdig typ som rekommenderas av apparattillverkaren Kassera använt batteri enligt gällande för...

Page 4: ...lied power from an outlet on the rack please make sure that the rack does not overload the supply circuit 2 Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack please confirm that the outlet is provided with a suitable protective earth connection 3 Internal air ambient temperature of the rack When this product is installed in a rack ...

Page 5: ...Installation Procedure 1 1 E 1 2 Supplied Accessories 1 1 E 1 3 Operating Conditions 1 2 E 1 4 Power Supply 1 3 E 1 5 Installation Space 1 4 E 1 5 1 Outside Dimensions 1 4 E 1 5 2 Notes on Installation 1 5 E 1 5 3 Rack Mounting 1 6 E 1 6 Connectors Cables 1 7 E 1 7 Signal Inputs and Outputs 1 8 E 1 8 Settings after Installation 1 11 E ...

Page 6: ......

Page 7: ...ce Manual volume 1 Available on request This manual describes detailed service overview error messages periodic check and maintenance replacement of main parts and alignments required for parts level service For obtaining contact your local Sony Sales Office Service Center Maintenance Manual volume 2 Available on request This manual describes detailed parts list block diagrams schematic diagrams a...

Page 8: ......

Page 9: ...erials 1 5 Installation Space Installation Section 1 Installation 1 1 Installation Procedure Installation procedure of this unit is shown on the following flowchart Refer to each section about detail of each flow The operation manual is also reqruired to do marked flow 1 2 Supplied Accessories Cap BNC 12 Cap DC OUT 1 Cap XLR F 2 Cap XLR M 4 Cap DUST 2 Operation manual Japanese 1 Operation manual E...

Page 10: ...l to prevent internal heat build up Place the unit in location with sufficient air circulation Do not block the ventilation holes of the cabinet and the front and rear panels Operating temperature 5 dC to 40 dC Operating humidity 25 to 90 Condensation not allowed Storage temperature _20 dC to 60 dC Locations to avoid Areas where the unit will be exposed to direct sunlight of any other strong light...

Page 11: ...g or checking the unit using AC power is recommended Power voltage 100 to 240 V AC 11 to 17 V DC Power consumption AC 80 W DC 65 W at power save mode 55 W n When using the battery check the remaining amount with the indicator on the side of the battery When the battery is nearly dead the battery indicator on the left side of the LCD panel will blink For details refer to the operation manual suppli...

Page 12: ...1 4 E PDW HD1500 IM 1 5 Installation Space 1 5 1 Outside Dimensions 210 132 9 5 12 5 396 4 71 373 3 174 Unit mm ...

Page 13: ...ovide 2 cm or more space to both the right and left sides and the top of the unit and 25 cm or more space behind the unit Do not install equipment on this unit n Provide 2 cm or more space to both right and left sides of the unit Providing 20 cm or more space above the unit is recommended considering service operations Battery Adapter Attachment When the unit is operated with a battery be sure to ...

Page 14: ...side leave 1 cm or more of space to the both side of each PDW HD1500 Blocking the air intake will damage the unit Leave 25 cm or more of space to the rear of the unit Use a commecially available rack mount kit Select an appropriate shelf taking size and weight of the unit into consideration Never remove the top and bottom panels handle or legs of the unit when installing Use adequately long cables...

Page 15: ... equivalent HDSDI OUTPUT Maximum cable length 100 m DIGITAL AUDIO AES EBU IN Reference value based on HDW series DIGITAL AUDIO AES EBU OUT ANALOG AUDIO INPUT XLR 3P MALE 1 508 084 00 _ ANALOG AUDIO OUTPUT XLR 3P FEMALE 1 508 083 00 _ AUDIO MONITOR DC IN XLR 4P FEMALE 1 508 362 00 DC power cord 1 551 577 00 supplied with AC 550 550CE REMOTE Plug 4P MALE 1 566 425 11 _ REMOTE 9P D sub 9P MALE 9P rem...

Page 16: ...r x1 for HKDV 900 connection Video control 9 REMOTE 9P D SUB 9P connector x1 RS 422A interface Remote control S400 i LINK 6P Conform to IEEE1394 Correspond to S400 NETWORK RJ 45 8P modular jack 10BASE T Conform to IEEE802 3i 100BASE TX Conform to IEEE802 3u 1000BASE T Conform to IEEE802 3ab 1 0 2 9 5 4 6 7 8 3 ...

Page 17: ...BT 656 2 COMPOSITE BNC x1 OUTPUT 1 Analog composite video 1 0 V p p 75 Z negative sync COMPOSITE BNC x1 Character superimpose enabled OUTPUT 2 Analog composite video 1 0 V p p 75 Z negative sync 3 REMOTE 4 pin connector x1 RM 280 DC 12 V 11 to 17 V 0 5 A max 4 TIME CODE OUT BNCx1 Time code 1 2 V p p 3 dB 75 Z load unbalanced HDSDI OUTPUT 1 BNC x1 Component digital 1 485 Gbits s SMPTE 292M HDSDI OU...

Page 18: ...Pin No Signal 1 GND 2 VPC_TX _ Output 3 VPC_RX Input 4 GND 5 NC 6 GND 7 VPC_TX Output 8 VPC_RX _ Input 9 GND 1 5 9 6 External View 1 5 9 6 External View 9 REMOTE 9P 9 pin female Pin No Signal 1 GND 2 RM TX _ Output 3 RM RX Input 4 GND 5 NC 6 GND 7 RM TX Output 8 RM RX _ Input 9 GND 5 DC IN 12V 4 pin male Pin No Signal 1 GND 2 NC 3 NC 4 EXT DC 3 REMOTE 4 pin female Pin No Signal 1 UNREG GND 2 NC 3 ...

Page 19: ... External View 8 1 External View External View 4 1 8 5 8 8 8 8 8 MAINTENANCE Pin No Signal 1 USB1_VBUS 2 USB1_D_ 3 USB1_D 4 GND 5 USB2_VBUS 6 USB2_D_ 7 USB2_D 8 GND NETWORK Pin No Signal I O 1 BI DA I O 2 BI DA_ I O 3 BI DB I O 4 BI DC I O 5 BI DC_ I O 6 BI DB_ I O 7 BI DD I O 8 BI DD_ I O 1 8 Settings after Installation For the settings after installation refer to the operation manual ...

Page 20: ......

Page 21: ...riftliche Erlaubnis der Sony Corporation SAFETY CHECK OUT After correcting the original service problem perform the following safety checks before releasing the set to the customer Check the metal trim metallized knobs screws and all other exposed metal parts for AC leakage Check leakage as described below LEAKAGE TEST The AC leakage from any exposed metal part to earth ground and from all exposed...

Page 22: ...Printed in Japan Sony Corporation 2008 2 16 2008 PDW HD1500 SY J E 3 398 656 01 ...