XBR-65X900A 17
SECTION 3 - REPAIR INFORMATION
18. Press
1
until
003 SERIAL
item displays.
DIGITAL
SERVICE
002 MODEL
003 SERIAL
19. Press
0
to display the
Serial Number Edit
option.
DIGITAL (MODEL)
SERVICE
SerialNumberEdit
*1 SerialNumber
20. Press
to display the
Serial Number
input screen.
DIGITAL (MODEL)
SERVICE
SerialNumberEdit
*1 SerialNumber
Please Input serial number
(0000000-99999999)
_ _ _ _ _ _ _
CAUTION: The Serial Number can only be selected once. Be sure
to verify the information is correct before saving the changes.
21. Enter the Serial Number of the TV.
NOTE:
If the incorrect Serial Number is entered, press
RETURN
to go back to the Serial Number input screen and re-enter
the correct number.
22. Press
to save the Serial Number.
DIGITAL (MODEL)
SERVICE
SerialNumberEdit
*1 SerialNumber
1800001
WRITE
23. Clear the
Self Check
screen.
a. Press
POWER
to exit
Service Mode
.
b. Press the following buttons on the
Remote Commander
within
1 second of each other:
DISPLAY
Channel
5
Volume
-
POWER
SELF CHECK
000 RESERVED
--------------------- --------------------- --------------------- 00
000 RESERVED
--------------------- --------------------- --------------------- 00
002 MAIN_POWE --------------------- --------------------- --------------------- 00
003 DC_ALERT
--------------------- --------------------- --------------------- 00
003 AUD_PROT
--------------------- --------------------- --------------------- 00
003 HDMI_EQ
--------------------- --------------------- --------------------- 00
003 TU_DEMOD --------------------- --------------------- --------------------- 00
004 VLED
--------------------- --------------------- --------------------- 00
004 LD_ERR
--------------------- --------------------- --------------------- 00
005 HFR_ERR
--------------------- --------------------- --------------------- 00
005 TCON_ERR
120123132522 120123113645 --------------------- 02
005 P_ID-ERR
--------------------- --------------------- --------------------- 00
006 BACKLITE
--------------------- --------------------- -------------------- 00
007 TEMP_ERR
--------------------- --------------------- --------------------- 00
007 FAN_ERR
--------------------- --------------------- --------------------- 00
010 EMITTER
--------------------- --------------------- --------------------- 00
101 VPC_WDT
--------------------- --------------------- --------------------- 00
102 MEPS_WDT --------------------- --------------------- --------------------- 00
103 HOST_WDT --------------------- --------------------- --------------------- 00
104 STBY_WDT
--------------------- --------------------- --------------------- 00
00345 000333 06789
Error Count
c. To clear the error history and error count press
8
0
.
d. Press
POWER
to exit
Self Check Mode
.
24. Cycle AC Power (Unplug and plug AC Cord from the outlet).