XAV-60/E60
18
2. V-COM ADJUSTMENT
Procedure:
1. The setting of “1. SETTINGS” is completed.
2. Connect an oscilloscope to TP1401 (VCOM) and TP1402
(GND) on the LCD board.
Check Location:
JL1401
(VCOM)
JL1402
(GND)
– LCD Board (Side B) –
3. Adjust by using the communication software so that the
waveform level of oscilloscope becomes 5.8 ± 0.1 V as fol-
lows.
5.8
±
0.1Vp-p
4. “dr1” is input by the communication software and “Enter” key
is pressed.
The following numerical value returns from the set.
“Read Channel1:0x**”
**: Hexadecimal (“00” to “FF”)
5. To change the adjusted value, “dw1 ##” is input by the com-
munication software and “Enter” key is pressed.
The following numerical value returns from the set.
“Write Channel1:0x##”
##: Hexadecimal (“00” to “FF”)
When waveform level is smaller than 5.8 V, the numerical
value of “##” is increase.
When waveform level is larger than 5.8 V, the numerical value
of “##” is decrease.
6. “ds” is input by the communication software and “Enter” key
is pressed and the numerical value is saved.
7. The “Reset” button is pressed and turn the power off.
Example:
When the returning numerical value “8a” and the waveform level
is 5.6 V.
The numerical value is increased, and adjusted for a waveform lev-
el to become 5.8 ± 0.1 V with “8b
:
8c
:
8d
:
8e
:
8f
:
90
:
91...”.
dr1
Read Channel1:0x8a
dw1 8b
Write Channel1:0x8b
dw1 8c
Write Channel1:0x8c
dw1 8d
Write Channel1:0x8d
ds
8
Reading of default value.
8
Default value.
8
The numerical value is in-
creased and confi rm.
8
Enters the range of
8
The numerical value is saved.
3. FLICKER ADJUSTMENT
Procedure:
1. The setting of “1. SETTINGS” is completed.
2. Input the PAL white 40% raster signal from AUX2 VIDEO IN
jack on the VISUAL board.
3. In the state of source off, press the [4]
:
[5]
:
[4] (keeps
pressing) button on the remote commander.
The test mode 4 starts, and the following screen is displayed on
the monitor.
4. “dr0” is input by the communication software and “Enter” key
is pressed.
The following numerical value returns from the set.
“Read Channel0:0x**”
**: Hexadecimal (“00” to “FF”)
5. To change the adjusted value, “dw0 ##” is input by the com-
munication software and “Enter” key is pressed.
The following numerical value returns from the set.
“Write Channel0:0x##”
##: Hexadecimal (“00” to “FF”)
Adjust so that the fl icker becomes minimum in the sight.
6. “ds” is input by the communication software and “Enter” key
is pressed and the numerical value is saved.
7. The “Reset” button is pressed and turn the power off.
Example of characteristic:
Flicker
Setting value (decimal)
bad
o
m
good
Summary of Contents for XAV-60 - 6.1 Inch Avc
Page 92: ...92 XAV 60 E60 MEMO ...