14
MZ-E909
3. If NG in the overall CD adjustments, return to Reset NV and
perform from the electrical offset adjustment again.
LCD display
XXX: NG item No.
4. If OK through the overall CD adjustments, then perform overall
MO adjustments.
LCD display
5. Insert MO disc in the set, and press
> N
key to set the
Overall MO Adjustment mode. Automatic adjustments are made.
LCD display
XXX: Item No. for which an adjustment is being executed.
6. If NG in the overall MO adjustments, return to Reset NV and
perform the adjustment again.
LCD display
XXX: NG item No.
7. If OK through the overall MO adjustments, press
x
key to
return to the TEST MODE and terminate the Overall Adjust-
ment mode.
LCD display
5-5-3.Resume clear method
1. Setting the testmode.
2. Set the Manual mode and set the item No.043(RESUME Clear).
LCD display
3. Press the
X
key.
LCD display
5-5-5. Overall CD and MO adjustment items
1. Overall offset adjustment
Item No.
Contents
030
GRV setting • Sarvo OFF • Head UP
035
Laser ON/OFF electrical offset difference
measurement
Completed
2. Overall CD adjustment items
Item No.
Contents
761
VC,VR power voltage High/Low selection
300
HPIT setting • Sarvo OFF
561
SLED move to inside
562
SLED move to outside
High reflection CD electrical offset adjustment
312
Laser ON • Focus UP • VC correction ALFA offset
adjustment
313
IJ offset adjustment
314
FE offset adjustment
HPIT adjustment
320
Focus servo ON
324
TE offset adjustment 1
321
TE gain adjustment
328
TWPP gain adjustment
324
TE offset adjustment 1
332
TE offset adjustment 2
330
Tracking servo ON
336
ABCD gain adjustment
337
KF gain correction
338
RF gain adjustment
344
CD focus gain adjustment
345
CD tracking gain adjustment
521
CD two-axis sensitivity adjustment (inside)
522
CD two-axis sensitivity adjustment (outside)
341
CD focus bias adjustment
300
HPIT setting • servo OFF
completed
XXX
NG
XXX
CD OK
XXX
MO RUN
000
MO OK
000
XXX
NG
043
Resume CC
043
Res ***
043
Res Clr
After reset is completed
LCD display
3. Overall MO adjustment items
Item No.
Contents
761
VC,VR power voltage High/Low selection
100
G RV setting
Low reflect MO offset adjustment
112
Laser ON • Focus UP • EVC correction ALFA offset
adjustment
113
IJ offset adjustment
114
FE offset adjustment
118
Wpp denominator adjustment
HPIT adjustmet
200
LPIT setting • servo OFF
561
SLED move to inside
220
Focus servo ON
224
TE offset adjustment 1
221
TE gain adjustment
224
TE offset adjustment 1
232
TE offset adjustment 2
5-5-4. Rewrite the NV value
After resume clear, rewrite the NV value.
Microprocessor version 1.0 to 2.0 : Step 1 and 2.
Microprocessor version 2.1 and later : Step 1 only
Step
Item NO.
NV value
1
861
0F (h)
862
0B (h)
2
863
87 (h)
864
75 (h)
Summary of Contents for Walkman MZ-E909