9
D-FS601
SECTION 4
ELECTRICAL ADJUSTMENTS
The CD section adjustments are done automatically in this set.
Precautions for Check
1. Perform check in the order given.
2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise
indicated.
3. Power supply voltage requirement : DC4.5 V in DC IN jack.
(J401)
VOLUME : Minimum
AVLS : OFF
HOLD switch : OFF
Focus bias Check
Condition:
• Hold the set in horizontal state.
• Terminate TAP802 (open) by solder.
Connection:
Procedure:
1. Connect the oscilloscope to the test points TJ629 (RF) on the
MAIN board.
2. Set a disc. (YEDS-18)
3. Press the
B/>
button.
4. Check the oscilloscope waveform is as shown below.
A good eye pattern means that the diamond shape (
◊
) in the
center of the waveform can be clearly distinguished.
RF Signal reference Waveform (Eye Pattern)
To watch the eye pattern, set the oscilloscope to AC range and
increase the vertical sensitivity of the oscilloscope for easy
watching.
5. Stop revolving of the disc motor by pressing the
x
button.
RF level
0.4 to 0.5 Vp-p
VOLT/DIV : 100 mV (With the 10 : 1 probe in use)
TIME/DIV : 500n
s
CD SECTION
TJ629 (RF)
2 K
Ω
Oscilloscope
(AC range)
IC601
IC801
IC302
[MAIN BOARD] (Side A)
[MAIN BOARD] (Side B)
TAP802 (OPEN)