2-1
VPL-PX35/PX40
Section 2
Electrical Adjustments
2-1. Preparation
2-1-1. Required Equipment
.
Oscilloscope
Tektronix 2465 or equivalent (350 MHz band width or
more)
.
NTSC, PAL, SECAM component signal generator
Tektronix TG2000
+
AVG1 (option module)
+
AWVG1
(option module) or equivalent
.
VG (programmable video signal generator)
VG814 or equivalent
.
Digital voltmeter
Advantest TR6845 or equivalent
.
Illuminance meter
n
Allow the warm-up time of 5 minutes after the power is on
before starting the following adjustments.
2-1-2. How to Enter the Factory Mode
1.
Confirm that the MENU can be displayed.
2.
Close the MENU.
3.
Press the keys in the following order :
[ENTER]
→
[ENTER]
→
[&]
→
[ENTER]
.
The message [Do you want to enter the Factory Mode?
Yes :
↑
No :
↓
] appears.
Select [Yes :
↑
].
[Supplementary information: How to Exit the
Factory Mode]
Perform the step 3 KEY operation.
The message [Do you want to return to the User Mode?
Yes :
↑
No :
↓
] appears.
Select [Yes :
↑
].
2-2. V COM Adjustment
1.
Input the green-only, 30 IRE single-line ON/OFF
signal to the input connector.
(XGA signal)
2.
Enter the G VCOM adjustment screen of the Device
Adjust.
3.
Adjust the G VCOM value so that the flicker is
minimal.
4.
Switch the input signal from green-only to red-only
(30 IRE) then to blue only (50 IRE) single-line ON/
OFF signal. In the same way as step 3, adjust the R
VCOM and B VCOM values respectively so that the
flicker is minimal.
5.
Take note of the adjustment values.
6.
Set the “Image Flip” to either V or HV.
7.
Input the above R/G/B adjustment values.
8.
Take note of the adjustment values.
9.
Set the “Image Flip” to OFF.
Summary of Contents for VPL-PX41
Page 6: ......
Page 38: ......
Page 40: ...4 2 VPL PX41 Top Cover 4 2 Exploded Views 2 8 5 6 11 1 9 4 10 7 10 3 ...
Page 134: ......
Page 136: ...English Sony EMCS Corporation 2005BR16 1 Ichinomiya Tec 2005 2 VPL PX41 SY E 9 872 746 01 ...