1-15
VPL-PX41
(3) ERROR LOG
Displays the situation where an error occurs. The past 10 errors are displayed.
DATE:
Year, month, and date when the error occurred
OP timer:
Operation time when the error occurred
Error:
Error description
LAMP FAILURE:
Lamp error
FAN FAILURE:
Fan error
COVER FAILURE:
Cover error
TEMP FAILURE:
Temperature error
POWER SYSTEM FAILURE 1:
Power supply error 1
POWER SYSTEM FAILURE 2:
Power supply error 2
TEMP WARNING:
Temperature warning
LOW RTC BATTERY:
RTC battery is low
(4) MAIL REPORT LOG
Displays the past 15 mail-send logs.
Date:
Year, month, and date the mail is sent
Time:
Time the mail is sent
Type:
Mail types
.
Test:
Test mail
.
Regular:
Periodical report
.
Maintenance:
Maintenance report
.
Error:
Error report
Result:
Displays the mail-send result.
.
OK:
Successfully sent
Error codes are displayed when mails cannot be sent. Table 1 shows the error codes.
Code
Error description
201
The receiver’s address, to_addr, is NULL or invalid.
202
Invalid message body, for example, NULL or invalid buffer pointer.
203
Invalid message size, for example, buflen<=0.
204
No server
205
No mailbox
206
TCP layer Error in transmitting message.
207
Email message cancelled (with MCDlete ())
208
mailbox syntax error
209
mailbox busy
213
Other errors
300
Login failed.
310
Logout failed.
401
Specified SMTP server not found.
402
Since there is no DNS setting, the server name cannot be changed to IP ADDRESS.
411
Specified POP server not found.
412
Since there is no DNS setting, the server name cannot be changed to IP ADDRESS.
500
Mail API initialization failed. (MCCreate function)
501
Mail API termination failed. (MCClose function)
Table 1. Error code table