1-30 (E)
VPL-EX100
1-6. Indicator
Display
In this unit, the error status is indicated by the blinking of the indicator. There are ON/STANDBY indica-
tor and LAMP/COVER indicator on the upper case. The error differs depending on which indicator
blinks.
For details of the blinking state of indicator and the error, refer to the list below.
ON/STANDBY indicator (Blinks in red)
Error
Number of
blinking
Status
Temperature error
ON
OFF
2
The temperature inside of the unit exceeds
the tolerable range.
Fan error
ON
OFF
4
Any of fan does not operate normally.
Power error
ON
OFF
6
The power is not output normally.
System error-1
ON
OFF
10
The data cannot be normally acquired from
the storage device (EEPROM) when the
power of sub-CPU is turned on.
System error-2
ON
OFF
11
The data cannot be normally acquired from
the storage device (EEPROM) when the
power of main-CPU is turned on.
System error-3
ON
OFF
12
The main-CPU does not operate normally.
System error-4
ON
OFF
13
The main-CPU does not operate normally.
Assembly error
ON
OFF
14
The connector of temperature sensor is
disconnected.
LAMP/COVER indicator (Blinks in red)
Error
Number of
blinking
Status
Cover error
ON
OFF
2
The lamp cover is removed.
Lamp error
ON
OFF
3
The lamp does not light normally.