![Sony TRINITRON KV-LX34M50 Service Manual Download Page 20](http://html.mh-extra.com/html/sony/trinitron-kv-lx34m50/trinitron-kv-lx34m50_service-manual_1330294020.webp)
– 20 –
KV-LX34M50
RM-871
SECTION 3
SELF DIAGNOSIS FUNCTION
When turning on the TV, a self diagnosis function is executed.
If no acknowledgement is returned from a device which is turned "ON", the device has a problem.
In this case, one of the LED's responding to the problem device will flicker a defined number of times.
The flickering frequency responding to each failed device is shown below.
Board name
Ref. No.
Device
Flickering Frequency
All the devices are checked one after another from the left of the table.
If an error is found, the responding LED will start flickering.
So, if more than 1 device has failed, only the one on the left side will flicker.
A Board
IC206
SURROUND
PROCESSOR
(TDA8424)
6
A Board
IC003
NONVOLATILE
MEMORY
1
A Board
IC104
MAIN Y/C
(CXA2050S)
3
A Board
IC1201
AV SWITCH
(CXA1855S)
2