– 6 –
KV-HR29M61/HR29N90/HR34M61/HR34N90
RM-1007
RM-1011
RM-1007
RM-1011
3.
Blinking count display of
1
or STANDBY/WAKE UP indicator
Lamp OFF :
3.0 seconds
Lamp ON : 0.3 seconds
Lamp OFF : 0.3 seconds
Release of
1
or STANDBY/WAKE UP indicator blinking.
•
The STAND BY indicator blinking display is released by turning OFF the power switch
on the TV main unit or removing the plug from the power.
But in the RLY ERR (10 times blinking), do not release by tuning power off.
For details, refer to the item 1-6.
*
One blink is not used for self-diagnosis.
•EXAMPLE
<Diagnosis Items> <Number of Blinks>
• +B overcurrent
2 times
• +B overvoltage
3 times
• Vertical deflection stop
4 times
< FRONT PANEL >
GE model
1
indicator
STANDBY/WAKE UP
Taiwan model
AUTO PROG
MENU
L(MONO)
R
4
PROG
4.
Self-diagnosis screen displays
•
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when
the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether
the detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
•
Quickly press the remote command button in the following order from the standby state.
˘
Be aware that this differs from the method of
entering the service mode ( + ).
b
b
b
5
–
=/1
<GE model>
<Taiwan model>
• "G" : OK, "NG" : DETECTS ONCE OR MORE
• THE 10 DIGITS OF NUMERALS ARE FOR CHECKING,
NO RELATION TO DIAGNOSIS.
• 101 : NO LED BLINKING FOR WDT.
"0" : NUMBER OF DETECTION.
Self-diagnosis screen display