- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
229
12.3.3. External Synchronization Phase Adjustment through Key Operations
External synchronization phase adjustment can be performed through key operations.
Parameters controlled through keys
During external synchronization phase adjustment, the parameters controlled through key operations
(SFTUP/SFTDWN) are SFTV and SFTH in “Table 12.2-32 Parameters Controlled by Key Operations“.
The SFTV/SFTH values adjusted through key operations are saved to the parameters in
. The
saved values (written to EEPROM when the keys are released) are applied to SFTV/SFTH during initialization.
Table 12.3-4 Parameters Controlled through Keys
Parameter
Description
SFTHL CAT7_Byte3_bit0-7 Horizontal
direction phase adjustment value (LSB)
SFTHM CAT7_Byte5_bit0-1 Horizontal
direction phase adjustment value (MSB)
SFTVL CAT7_Byte4_bit0-7
Vertical
direction phase adjustment value (LSB)
SFTVM CAT7_Byte5_bit2-3
Vertical
direction phase adjustment value (MSB)
Table 12.3-5 Parameters for saving SFTV/SFTH adjustment values
Parameter
Description
CTRLSFTHL CAT17_Byte1_bit0-7 Parameter
for
saving SFTH adjustment value at key release (LSB)
CTRLSFTHM CAT17_Byte2_bit0-1 Parameter for saving SFTH adjustment value at key release (MSB)
CTRLSFTVL CAT17_Byte3_bit0-7 Parameter
for
saving SFTV adjustment value at key release (LSB)
CTRLSFTVM CAT17_Byte4_bit0-1 Parameter for saving SFTV adjustment value at key release (MSB)
Phase adjustment parameters when using presets
Presets are applied when both SFTUP and SFTDWN are set to “1[h]”.
When presets are applied, the values set in the parameters of
(PRSTSFTH and PRSTSFTV) are
applied to SFTH or SFTV.
Table 12.3-6 Phase adjustment parameters when using presets
Parameter
Description
PRSTSFTHL
CAT17_Byte13_bit0-7
SFTH setting for presets (LSB)
PRSTSFTHM
CAT17_Byte14_bit0-1
SFTH setting for presets (MSB)
PRSTSFTVL
CAT17_Byte15_bit0-7
SFTV setting for presets (LSB)
PRSTSFTVM
CAT17_Byte16_bit0-1
SFTV setting for presets (MSB)
* See 12.2 “Using external synchronization” for information on the phase adjustment parameters that are not
controlled through keys.