2-17
SRX-T420
2-5. Illumination Area Adjustment and Registration Adjustment
2-5-1. Illumination Area Adjustment
If there is any deviation of illumination range when installing the unit, perform adjustment in the follow-
ing procedure.
n
The adjustment cannot be correctly performed with the
fi
lter cover open because the
fi
lter cover switch
sensor function operates. Before starting the adjustment, be sure to close the
fi
lter cover after removing
the panel duct covers.
Procedure
1. Remove the panel (U7) block assembly. (Refer to Section 1-1-2.)
2. Remove the panel (U2) block assembly. (Refer to Section 1-1-3.)
3. Remove
the
fi
lter.
4. Remove
the
fi
ve screws.
Filter cover
Front side
Filter cover switch
Filter (center portion)
Screws
Front side
Fig. 2-5-1a
Fig. 2-5-1b
Summary of Contents for SRX-T420