2-12
SRX-T420
2-3. Optical Axis Adjustment of Lamp Bulb
Procedure
1. Be sure to click the “SERVICE” tab in the standby state.
The SERVICE window is displayed.
2. Click
the
[SELECT]
button in a “LAMP ADJUST & TIMER RESET” menu.
LAMP INFORMATION window is displayed.
3. Enter the serial code described in the Operating Instructions of a lamp bulb in the “Serial Code” box
and click the
[CHECK]
button.
m
.
Be sure to perform in the standby state.
.
Enter the serial code with the space not put.
4. Click
the
[CLOSE]
button and close the LAMP INFORMATION window.
5. Click
the
[ON]
button of POWER.
“SERVICE” tab
[ON]
button
“LAMP ADJUST & TIMER RESET” menu
Fig. 2-3a
“LAMP ADJUST” menu
Enter the serial code.
[CHECK]
button
[CLOSE]
button
[START]
button
Fig. 2-3b