— 9 —
•
Switch Location
VOLUME
: MAX
MEGA BASS : OFF
AVLS
: NORMAL
[AM]
BAND: AM
Signal generator
[FM]
BAND : FM
Signal generator
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
620kHz
CT1
1,400kHz
TUNER SECTION
Put the lead-wire
antenna close to
the set.
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
AM RF signal
generator
0.01
µ
F
FM RF signal
generator
FM IN
point
75kHz(100%) amplitude modulation
by 1kHz signal.
Output level: as low as possible
16
Ω
set
level meter
J301 (phones)
•
Repeat the procedures in each adjustment several times for the
maximum level meter indication.
•
The frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz
CT4
1,750kHz[1,680kHz]
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5MHz
CT2
109.5MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
86.5MHz
CT3
109.5MHz
Adjustment Location: Main board (See page 10)
0 dB = 1 µV
[
] : AEP, E Model