![Sony PXW-FS7 Service Manual Download Page 27](http://html.mh-extra.com/html/sony/pxw-fs7/pxw-fs7_service-manual_1323790027.webp)
Self-diagnosis
Code
Symptom/State
Correction
E91-357
Memory error of IC0201 on the
VIF-58 board
IC0201 and IC0300 on the VIF-58 board or the peripheral circuit may
be faulty.
Replace the VIF-58 board.
E91-360
Communication error between
IC0100 on the DPR-365 board and
extension unit
IC0100 on the DPR-365 board and CN3005 on the IF-1270 board, or
the peripheral circuit may be faulty.
Check the connection between DPR-365 board and IF-1270 board.
And check the connection of the extension connector (CN3005 on the
IF-1270 board).
Replace the faulty DPR-365 board and/or the IF-1270 board.
E91-367
Memory error of IC0201 on the
VIF-58 board
IC0201 and IC0300 on the VIF-58 board or the peripheral circuit may
be faulty.
Replace the VIF-58 board.
E91-377
Operation fault of IC0800 on the
VIF-58 board
IC0100 on the DPR-365 board and IC0800 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
E91-380
Communication error of IC0100 on
the DPR-365 board
IC0100 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E91-390
Communication error between
IC0100 on the DPR-365 board and
IC0400 on the VIF-58 board
IC0100 on the DPR-365 board and IC0400 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
E91-610
*1
Abnormality of steadyshot circuit
Turn the power off and on again.
E91-61E
*1
Abnormality of IC for steadyshot
Turn the power off and on again.
E91-623
*1
Abnormality of steadyshot circuit
Turn the power off and on again.
E91-627
*1
Abnormality of IC for steadyshot
Turn the power off and on again.
E92-204
Communication error between
IC0100 and IC1700 on the DPR-365
board
IC0100 and IC1700 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E92-205
Communication error between
IC0100 and IC1700 on the DPR-365
board
IC0100 and IC1700 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E92-206
Communication error between
IC0100 and IC1700 on the DPR-365
board
IC0100 and IC1700 on the DPR-365 board, or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E92-303
Communication error between
IC0100 and IC2901 on the DPR-365
board
IC0100 and IC2901 on the DPR-365 board or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
E95-124
*1
Abnormal termination of Wi-Fi
module firmware upgrade
Turn the power off and on again.
E95-201
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-202
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-203
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-204
Operation fault of IC1700 on the
DPR-365
IC1700 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-205
Operation fault of IC1200 on the
DPR-365
IC1200 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-206
Operation fault of IC1200 on the
DPR-365
IC1200 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-207
Operation fault of IC1200 on the
DPR-365
IC1200 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
E95-311
Operation fault of IC0100 on the
DPR-365
IC0100 on the DPR-365 board or the peripheral circuit may be faulty.
Replace the DPR-365 board.
Continued
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
1-3
Summary of Contents for PXW-FS7
Page 1: ...SOLID STATE MEMORY CAMCORDER PXW FS7 PXW FS7K SERVICE MANUAL 1st Edition Revised 3 ...
Page 6: ......
Page 8: ......
Page 14: ......
Page 16: ......
Page 22: ......
Page 24: ......
Page 36: ......
Page 38: ......
Page 44: ...2 2 修理時の電源供給について 2 2 1 AC アダプタ 修理時の電源供給については 必ず AC アダプタを使用してください PXW FS7 PXW FS7K 2 2 ...
Page 50: ......
Page 52: ......
Page 84: ......
Page 146: ......
Page 270: ......
Page 275: ...DC 177 CN1400 C1400 J1400 1 5 6 4 3 1 2 DC 177 BOARD 1 894 230 11 DC IN PXW FS7 PXW FS7K 9 5 ...
Page 292: ......
Page 294: ......
Page 295: ......