24
System Screen
Chap
ter
4
W
eb Men
u
2-IN 3-OUT
When the system configuration is 2-in/3-out, this enables
operation with input port syncing.
GPIO Parallel Input Setup
Assigns the commands for the input side of the GPIO (25-
pin) connector.
A 32-byte setting can be specified for pin 1 to pin 11.
GPIO Parallel Output Setup
Assigns the commands for the output side of the GPIO (25-
pin) connector.
A 32-byte setting can be specified for pin 13 to pin 24.
For details about commands, refer to the Interface Manual.
Network tab
Makes network settings.
Network 1 (1G)
Sets the IP address, subnet mask, and default gateway of
the NETWORK 1 connector.
The following values are the factory default values.
IP Address: 192.168.0.1
Subnet Mask: 255.255.255.0
Default Gateway: 0.0.0.0
Network 2 (1G)
Sets the IP address and subnet mask of the NETWORK 2
connector.
The default gateway setting for Network 1 is displayed.
The following values are the factory default values.
IP Address: 192.168.0.2
Subnet Mask: 255.255.255.0
Extended Board (10G)
When an optional 10 Gigabit network is used, this sets the
IP address, subnet mask, default gateway, and MTU.
The following values are the factory default values.
IP Address: 192.168.0.10
Subnet Mask: 255.255.255.0
Default Gateway: 0.0.0.0
MTU: 1500