INTERFACE UNIT

PFV-L10

INSTALLATION MANUAL
2nd Edition (Revised 1)
Serial No. 17001 and Higher

Summary of Contents for PFV-L10

Page 1: ...INTERFACE UNIT PFV L10 INSTALLATION MANUAL 2nd Edition Revised 1 Serial No 17001 and Higher ...

Page 2: ...e uniquement PFV L10 5 Install the equipment while taking the operating temperature of the equipment into consideration For the operating temperature of the equipment refer to the specifications of the Operation Manual 6 When performing the installation keep the rear of the unit 10 cm 4 inches or more away from walls in order to obtain proper exhaust and radiation of heat For the U S A Attention w...

Page 3: ...g Environment 1 1 E 1 3 Power Supply 1 2 E 1 3 1 Power Supply Specifications 1 2 E 1 3 2 Recommended Power Cord 1 2 E 1 4 Installation Space 1 3 E 1 5 Installing Optional Board 1 4 E 1 6 Rack Mounting 1 6 E 1 6 1 Notes on Rack Mounting 1 6 E 1 6 2 Rack Mounting Procedure 1 7 E 1 7 Matching Connector 1 8 E 1 8 Signal Inputs Outputs 1 8 E 1 9 Optional Accessories 1 8 E ...

Page 4: ......

Page 5: ...ass of the unit 1 3 Power Supply This section describes the power supply recommended power cord and the notes for power supply 1 4 Installation Space This section describes the dimensions of the unit 1 5 Installing Optional Board This section explains the installation procedure of the optional board 1 6 Rack Mounting This section explains the rack mounting procedure of the unit in the 19 inch stan...

Page 6: ...This manual describes the notes on operating the locations and functions of parts and controls of PFV L10 Maintenance Manual Available on request This manual describes the information for periodic maintenance and detailed service If this manual is required please contact your local Sony Sales Office Service Center ...

Page 7: ...procedure of PFV L10 is as shown in the following flowchart Refer to the each item in this manual for details 1 2 Operating Environment Operating temperature 5 dC to 40 dC Performance temperature 10 dC to 35 dC Humidity 10 to 90 No condensation Mass Approx 7 kg Without the optional board To prevent overheating of PFV L10 ensure that there is good air circulation around the unit n Install in a stab...

Page 8: ...ervice Center w Never use an injured power cord For customers in the U S A and Canada Required Part 1 Power cord 125 V 10 A 2 4 m 1 557 377 11 For customers in the United Kingdom Required Part 2 Power cord 250 V 10 A 2 4 m 1 782 929 21 If the unit is used in the area except above please contact your local Sony Sales Office Service Center 1 3 Power Supply 1 3 1 Power Supply Specifications Power vol...

Page 9: ...on holes of the unit Both of the front and rear sides must be at least 20 cm away from the walls for ventilation and mainte nance The outer dimensions of PFV L10 are as shown here 1 4 Installation Space 15 3 3 M4 76 2 353 2 91 7 231 115 5 31 88 2U 465 440 482 Unit mm ...

Page 10: ...lot label supplied with the optional board onto the board lever 6 Reinstall the board retainer 7 Reinstall the front panel n When removing the main board turn the board lever in the direction of the arrow 2 and pull out the board to ward you 1 5 Installing Optional Board The optional board can be installed in any empty slot of PFV L10 Installing Main Board Front side 1 Turn off the power switches ...

Page 11: ...nel of the slot which contains the main board n Keep the blank panel which is removed 2 Connect the connector panel to the MB 862 board 3 Secure the connector panel with the two screws securing the blank panel n Do not open the slot for an air cooled effect of this unit Attach the blank panel to a empty slot B 2 6x4 Blank panel B 2 6x4 Connector panel 1 5 Installing Optional Board ...

Page 12: ...parts are required Screws RK 5x16 7 682 378 04 4 pieces Ornamental washers 2 297 913 01 4 pieces 1 6 1 Notes on Rack Mounting w Fix the rack on the horizontal and firm floor with bolts to prevent it from turning over or moving If the rack overturn due to the weight of the unit this may cause a death or serious injury Use the specified rack mounting kit If not the unit may fall because of insuffici...

Page 13: ...ft side n The maximum depth of an adaptor is 750 mm The minimum depth of an adaptor is 595 mm 3 Firmly lay the right and left adaptors in the rack with the specified six screws Following figure is case of left side 4 Fasten the length adjustment screws which are loos ened in step 2 5 Align the crook of the each rack bracket on the side panels of the unit with the rail then slide the unit backward ...

Page 14: ...18 through 22 1 566 493 21 AWG 22 through 24 1 564 774 11 AWG 24 through 28 1 567 775 11 1 8 Signal Inputs Outputs The input and output signals of the connectors on the connector panel are as shown here STATUS OUTPUT D sub 15 pin FEMALE Pin No I O Signal 1 OUT DIAG 1 2 OUT DIAG 2 3 OUT DIAG 3 4 OUT DIAG 4 5 OUT DIAG 5 6 OUT DIAG 6 7 OUT DIAG 7 8 OUT DIAG 8 9 OUT DIAG 9 10 OUT DIAG PS B 11 OUT DIAG...

Page 15: ...acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschließli...

Page 16: ...Printed in Japan Sony Corporation 2004 12 22 B P Company 2002 PFV L10 SY J E 3 202 581 12 ...