3-5
PFM-32C1/32C1E
9. Detecting PDP initialization error
(1) PDP Init : In the case of the PDP unit initialization
error, the “NG” indication is displayed.
10. Detecting chroma decoder initialization error
(1) DEC Init :In the case of the chroma decoder unit
initialization error, the “NG” indication is
displayed.
Service Mode
Service Status
Warning Status
EEP ID
:
OK
EEP Save
:
OK
EEP Load
:
OK
RTC Init
:
OK
RTC VDET
:
OK
RTC XSTOP
:
OK
PDP Init
:
OK
(1)
DEC Init
:
OK
DC Init
:
OK
Power Off
:
OK
Service Mode
Service Status
Warning Status
EEP ID
:
OK
EEP Save
:
OK
EEP Load
:
OK
RTC Init
:
OK
RTC VDET
:
OK
RTC XSTOP
:
OK
PDP Init
:
OK
DEC Init
:
OK
(1)
DC Init
:
OK
Power Off
:
OK
11. Detecting abnormal voltage of the internal
power supply and shutting power supply
down
(1) DC Init : When the internal power supply (digital
system 5 V, digital system 3.3 V or analog
system 6 V) does not start up, the “NG”
indication is displayed.
If any one of these power supplies does not
start up, the shutting-down operation is
activated and this indication is stored in log
after the PDP unit returns to the normal
operation.
12. Detecting abnormal power-off sequence
(1) Power Off : If the power-off sequence is not per-
formed correctly, “NG” is displayed.
Failure of the power supply block or
failure of the PDP is suspected.
Service Mode
Service Status
Warning Status
EEP ID
:
OK
EEP Save
:
OK
EEP Load
:
OK
RTC Init
:
OK
RTC VDET
:
OK
RTC XSTOP
:
OK
PDP Init
:
OK
DEC Init
:
OK
DC Init
:
OK
(1)
Power Off
:
OK
Service Mode
Service Status
Warning Status
EEP ID
:
OK
EEP Save
:
OK
EEP Load
:
OK
RTC Init
:
OK
RTC VDET
:
OK
RTC XSTOP
:
OK
PDP Init
:
OK
DEC Init
:
OK
DC Init
:
OK
Power Off
:
OK
(1)
Summary of Contents for PFM-32C1
Page 16: ......
Page 44: ......
Page 52: ...5 6 PFM 32C1 32C1E 206 210 205 207 216 201 203 202 213 214 204 215 217 Packing Group ...
Page 72: ......
Page 98: ......
Page 100: ...Sony Corporation B P Company 9 870 331 01 English 02FS16 1 Printed in Japan 2002 6 ...