117
Troubleshooting
A
ppe
ndix
During recording operations
MAX # Clips
No more clips can be recorded because the maximum number of recorded clips has been
reached.
Delete unneeded clips.
Media Full!
Recording or copying is not possible because the media is full.
Delete unneeded clips.
TC EXT!
This appears when TCG on page P4 TC of the function menu is set to “EXT”, and you try to preset
timecode or user bits by setting PRST/RGN to “PRESET”.
Set TCG to “INT”
.
REGEN mode!
This appears when PRST/RGN on page P4 TC of the function menu is set to “TC” or “VITC”, and
you try to preset timecode or user bits.
Set PRST/RGN to “PRESET”
.
REC mode!
Stop recording and try again.
Exit THUMBNAIL mode!
This appears when an attempt is made to change media while the clip list screen is displayed.
Switch to the basic operation screen or the video monitor screen and try the operation again.
REMOTE!
Press the REMOTE button, turning it off, to put this unit into local control mode.
No Disc!
Insert a Professional Disc and try the operation again.
Media Top!
An attempt has been made to execute a reverse search when the unit is stopped at the first frame
of the first clip during playback of a disc.
Media End!
An attempt has been made to execute a forward search when the unit is stopped at the last frame
of the last clip during playback of a disc.
REC INHI.!
Set the Write Inhibit tab on the disc so as to enable recording
.
No EM Space
This appears when any essence mark was not recorded because there is no space before and
after the desired position.
Delete unneeded shot marks 0 to 9 on the chapter thumbnail screen.
EM Full!
This appears when no more essence marks can be recorded.
Delete unneeded shot marks 0 to 9 on the chapter thumbnail screen.
Illegal Operation!
This appears when an attempt is made to carry out an invalid operation.
Media is not Ready.
The media is in the course of being mounted or has not been loaded.
Alarm message in status
display area
Alarm message on video monitor
screen
Description/action
Input Sig!
VIDEO INPUT SIGNAL DOES NOT
MATCH SYSTEM SETUP.
This appears when the signal that does not
correspond to the system frequency or the number of
lines set in this unit is being input, or when HD-SDI is
selected as a video input signal while set for SD
signal recording.
Input a signal that matches the system frequency, or
change this unit’s system frequency setting
REC INH!
THE DISC WRITE PROTECT TAB IS SET
TO SAVE.
Set the write protect tab of the disc to allow recording
.
ILL. REC!
ENCODING DOES NOT SYNCHRONIZE
WITH REF VIDEO.
Check the signals being input to this unit.
MEM. Full!
MEMORY FULL !!
Recording on the disc is not possible because a
buffer overflow has occurred in the recording buffer
memory.
Verify ERR!
DISC ERROR DETECTED.
The Verify function detected an abnormality in signals
recorded on the disc.
Replace the disc.
Alarm message in status
display area
Description/action