NWZ-S515/S516/S615F/S616F/S618F
2
NOTE THE LCD SUB ASSY (LCD801) REPLACING
The LCD sub assy (LCD801) used with this main unit has two
kinds of types of made by EPSON and made by TMD.
When the LCD sub assy (LCD801) is replaced, it is necessary to
write information on LCD used in the main board.
When the LCD sub assy (LCD801) is replaced, when it is sure to
ful
fi
ll the conditions referring to “1. Discrimination” and “2. Con-
dition to use the LCD Con
fi
g Setting Tool”, information on LCD
used for the main board is written according to “3. Prior prepara-
tion”, “4. Updating the
fi
rmware of the main unit” and “5. Use of
the LCD Con
fi
g Setting Tool”.
• Part No. of the LCD sub assy (LCD801)
made by EPSON
made by TMD
X-2187-040-1
X-2189-452-1
• About the service supply parts of the LCD sub assy
(LCD801)
The LCD sub assy (LCD801) made of EPSON is substituted by the
LCD sub assy (LCD801) made of TMD as soon as the stock of the
service supply parts is digested.
Therefore, all the service supply parts are integrated into the LCD
sub assy (LCD801) made of TMD in the futures.
1. Discrimination
LCD made by EPSON
LCD made by TMD
"A01065300" is marked.
Serial number is marked.
Not marked.
Serial number is pasted.
2. Condition to use the LCD Con
fi
g Setting Tool
When corresponding to the following condition, write information
on LCD that uses the LCD Con
fi
g Setting Tool and uses it for the
main board.
• When the LCD sub assy (LCD801) made of EPSON breaks
down, and change parts are the LCD sub assy (LCD801) made
of TMD.
• When the LCD sub assy (LCD801) made of TMD breaks
down, and change parts are the LCD sub assy (LCD801) made
of EPSON.
• When nothing is displayed in LCD by the energizing con
fi
rma-
tion after the main board is replaced.
3. Prior preparation
Procedure:
1. Following jig is prepared.
• PC (OS: since Windows XP)
• LCD
Con
fi
g Setting Tool (Con
fi
rm the obtaining method to
each service headquarters)
2. Unzip the zip
fi
le of the LCD Con
fi
g Setting Tool.
3. Copy two made folders (“LCD_EPSON” and “LCD_TMD”)
onto the right under of C drive of PC.
Note:
There is no problem wherever the made folder is preserved.
In “5. Use of the LCD Con
fi
g Setting Tool”, it explains assuming
that the folder is preserved right under C drive.
4. Updating the
fi
rmware of the main unit
(US and Canadian models only)
To use the LCD Con
fi
g Setting Tool, the
fi
rmware of the main unit
must be 1.00.51 or later.
As factory side has shipped the main unit with
fi
rmware Version
1.00.50 to US and Canadian, please check the
fi
rmware version
of the main unit with test mode before using LCD Con
fi
g Setting
Tool.
If the
fi
rmware version is 1.00.50, please update the
fi
rmware to
1.00.51.
Procedure:
1. Following jig is prepared.
• PC (OS: since Windows XP)
• F/W Updater (Con
fi
rm the obtaining method to each service
headquarters)
2. Unzip the zip
fi
le of the F/W Updater to get “10051-NWZ-
S61X” folder.
3. Open the “PGImage-NWZ-S61X” folder under the folder in
step 2.
4. Start
FWUpdater.exe
fi
le.
5. Select “I agree.” and click next button.