26
HCD-CZ1/NAS-CZ1
Note:
1.
CD Block is basically constructed to operate without adjustment.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10 M
Ω
impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
5.
Check the focus bias check when optical block is replaced.
FOCUS BIAS CHECK
Procedure :
1. Connect the oscilloscope to TP (RFACO) and TP (VC) on the
CD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the
CD
u
button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊
) in the
center of the waveform can be clearly distinguished.
•
RF signal reference waveform (eye pattern)
CD SECTION
SECTION 5
ELECTRICAL ADJUSTMENTS
+
–
CD board
TP (RFACO)
TP (VC)
oscilloscope
(DC range)
Checking Location:
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
1.1
When observing the eye pattern, set the oscilloscope
for AC range and raise vertical sensitivity.
0.2 Vp-p
TP
(RFACO)
TP (VC)
– CD BOARD (Conductor Side) –