– 12 –
SECTION 4
TEST MODE
4-1. GENERAL
This set pr ovides the Overall adjustment mode (Assy mode) that
allo ws CD and MO disk to be automaticall
y adjusted when in the
test mode . In this Assy mode
, the system discriminates between
CD and MO disk and then automatically perform adjustments for
them in sequence
. If a fault is f ound, the system displa
ys its loca-
tion. Also, the Ser vo mode allo ws eac h individual adjustment to be
automatically adjusted.
4-2. TEST MODE SETTING
See page 5.
4-3. TEST MODE STRUCTURE
Test mode
4-4. MANUAL MODE
(1) Servo Mode
• How to Transfer in the Servo Mode:
Mode No.
Test Description
Check
Write
000
Servo mode
010
Offset correction value indication
011
VC offset correction
012
Focus bias correction
013
FE offset correction
014
ABCD offset correction
015
All servo ON
016
Temperature indication
020
Laser power adjustment
021
Laser CD/MO read adjustment
®
(08)
022
Laser MO write adjustment
®
(4C)
023
Sled normal
®
(45)
024
Sled intermittent
®
(65)
025
Sled access
®
(30)
030
MO test adjustment
031
MO focus search adjustment
032
MO read FE balance adjustment
®
(0F)
033
MO read ABCD level
®
(07)
034
MO write FE balance adjustment
®
(10)
035
MO write ABCD level
®
(18)
036
Laser MO read adjustment
®
(08)
037
MO focus gain
®
(30)
038
MO tracking gain
®
(30)
039
MO focus bias
®
®
(06)
040
Low reflection CD test adjustment
041
Low reflection CD focus search adjustment
042
Low reflection CD FE balance adjustment
®
(10)
043
Low reflection CD ABCD level
®
(06)
044
Laser low reflection CD read
®
(08)
045
Low reflection CD focus gain
®
(30)
046
Low reflection CD tracking gain
®
(30)
Mode No.
Test Description
Check
Write
047
Low reflection CD focus bias
®
®
(00)
050
CD test adjustment
051
CD focus search adjustment
052
CD FE balance adjustment
®
(10)
053
CD ABCD level adjustment
®
(15)
054
Laser CD read
®
(08)
055
CD focus gain
®
(30)
056
CD tracking gain
®
(30)
057
CD focus bias
®
®
(00)
060
Recording test
061
32 cluster full recording
062
Recording shock
063
32 cluster full playback
Check : Mode to displa
y err or rate and c
luster .
Write : Mode to permit adjustment (Default v
alue given in paren
theses).
1. Go into the test mode.
2. Press
+
or VOLUME + ke y to set the ser
vo mode .
Unit LCD display
3. Press the ke
ys belo w to c hang e the mode No.
(
: Increases the one place.
p
: Sets the one place to 0.
This ke y brings the ten place to 0 if the one place is
0.
VOLUME + : Increases the ten place by 10 if the one place is 0.
Increases the adjustment v
alue if the one place
is non-zero.
VOLUME – : Decreases the ten place by 10 if the one place is 0.
Decreases the adjustment v
alue if the one place is
non-zero.
• How to Adjust in Servo Mode:
1. When the ser
vo mode is set to the appr
opriate mode f
or eac h
adjustment, the lo wer to w digits of the mode No.
and the v alue
stored in EEPR
OM are displa yed and flashing.
SERVO
XX XX
Adjustment value
(the data can be changed/
written when flashing.)
Mode No.
(The lower two digits are indicated.
Three digits are indicated on the
remote controller LCD.)
SERVO
XX XX
Adjustment value (flashing)
Mode No. (lower two digits)
Manual Mode
Servo Mode
Audio Mode
Mechanism Mode
Power Mode
or VOLUME key
VOLUME key
Overall Adjustment Mode
or VOLUME key
Hybrid Mode (ALL Mode)
+
–
+
=
+
EDIT/ENTER key
MODE key
Key Check Mode
(Assy Mode)
Summary of Contents for MZ-R55
Page 4: ... 4 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 11: ... 11 3 9 HOLDER ASSY 3 10 OP BLOCK ASSY 1 M1 4x3 0 2 OP block assy 1 claw 4 holder assy 2 3 ...
Page 48: ... 4 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 55: ... 11 3 9 HOLDER ASSY 1 claw 4 holder assy 2 3 ...
Page 90: ... 4 SECTION 1 GENERAL This section is extracted from instruction manual ...
Page 97: ... 11 3 9 HOLDER ASSY 1 claw 4 holder assy 2 3 ...