17
MZ-N1
Jog and Key Check Mode
This set can check if the set and remote commander function nor-
mally.
• Setting method of jog check mode
1. Set the test mode (see page 13).
2. Press the jog button to activate the jog check mode and display as
below.
3. Turn the jog dial downwards one click.
4. Turn the jog dial downwards three more clicks.
5. Turn the jog dial upwards one click.
6. Turn the jog dial upwards three more clicks.
7. When the
x
/
CHG
key is pressed, it changes over to the key
check mode.
Note:
To enter the key check mode, it is not necessary to enter via the jog
dial check mode. (Refer to next item)
• Setting method of key check mode
1. Set the test mode (see page 13).
2. Press the
[T MARK]
key or
[DISPLAY]
key on the remote com-
mander for several seconds (about 3 seconds) activates the key
check mode. (At the last two digits, AD value of remote com-
mander key line is displayed in hexadecimal)
3. When each key on the set and on remote commander is pressed,
its name is displayed on the remote commander LCD. (The
operated position is displayed for 4 seconds after the slide
switch is operated. If any other key is pressed during this dis-
play, the remote commander LCD switches to its name dis-
play)
Sound Skip Check Result Display Mode
This set can display the count of errors that occurred during the
recording/playing for checking.
• Setting method of sound skip check result display
mode
1. Set the test mode (see page 13).
2. Press the
N
key or
[REC]
key, and the playing or recording
sound skip result display mode becomes active respectively
where the LCD displays the following.
3. When the
N
key is pressed, total error count is displayed on
the LCD, and each time the
>
key is pressed, the display
item moves down by one as shown below. Also, if the
.
key
is pressed, the display item moves up by one, then if the
[REC]
key is pressed, the display in the record mode appears.
When the
[REC]
key is pressed, total error count is displayed
on the LCD, and each time the
>
key is pressed, the display
item moves down by one as shown below. Also, if the
.
key
is pressed, the display item moves up by one, then if
the
N
key is pressed, the display in the play mode appears.
• Cause of sound skip error
Cause of error
Description of error
EIB
Sound error correction error
Play
Stat
Decoder status error
Adrs
Address access error
BEmp
Buffer is empty
BOvr
Buffer is full, and sounds were
dumped
Record
Bful
Buffer capacity becomes less,
and forcible writing occurred
Rtry
Retry times over
4. To quit the sound skip check result display mode and to return
to the test mode (display check mode), press the
x
/
CHG
key.
Remote commander LCD display
Total count of play
system errors (hex.)
Total count of record
system errors (hex.)
P * * R * *
000
000
P * * R * *
000
E I B * *
000
S t a t * *
000
A d r s * *
000
B E m p * *
000
# # # # # #
000
P * * R * *
000
B O v r * *
000
B f u l * *
000
R t r y * *
000
# # # # # #
P**R**
: Total play/record errors (hex.)
**
: Counter of sound skip check each item (hex.)
######
: 6-digit address where sound was skipped last (hex.)
Playing sound skip
result display
Recording sound skip
result display
Remote commander LCD display
PUSH
000
Remote commander LCD display
JOG+ 1
000
Remote commander LCD display
JOG+OK
000
Remote commander LCD display
JOG- 1
000
Remote commander LCD display
JOG OK
000
Remote commander LCD display
**
000
**
: AD value of the remote commander key