13
MZ-N1
Operation in Setting the Test Mode
• When the test mode becomes active, first the display check mode
is selected.
• Other mode can be selected from the display check mode.
• When the test mode is set, the LCD repeats the following dis-
play.
Remote commander LCD display
•
When the
X
key is pressed and hold down, the display at that
time is held so that display can be checked.
Releasing the Test Mode
For test mode set with the method
1
:
Turn off the power and open the solder bridge on SL801 (TEST)
on the MAIN board.
Note:
Remove the solders completely. Remaining could be shorted with
the chassis, etc.
For test mode set with the method
2
or
3
:
Turn off the power.
888
001
V1.000
Microcomputer
version
display
All off
All lit
C510
C511
R842
R841
C509
FB802
FB801
C821
C818
C813
C850
C820
+
C810
+
195 199 178 174 170 166 164 158 1
203 180 176 172 168 162 160 1
175 171 169 167 163 159 1
197
193
191
189
185
187
173 179 177 201 165 161 1
183
182
207 181
184
186
215 188
209
190
SL506
SL801
(TEST)
SL801
(TEST)
S801
[HOLD]
switch
OFF
t
ON (HOLD)
– MAIN Board (Conductor Side) –
2
In the normal mode, turn on the
[HOLD]
switch. While press-
ing the
[VOLUME --]
key press the following order:
>
t
>
t
.
t
.
t
>
t
.
t
>
t
.
t
X
t
X
3
In the normal mode, turn on the
[HOLD]
switch. While
pressing the
x
/
CHG
key, press the keys on the remote
commander with the following order:
N >
t
N >
t
.
t
.
t
N >
t
.
t
N >
t
.
t
X
t
X
Note:
If electrical adjustment (CD and MO overall adjustment) has not
been finished completely, “NV Error” is displayed on LCDs of the
set and the remote commander.
SECTION 4
TEST MODE
Outline
• This set provides the Overall adjustment mode that allows CD
and MO discs to be automatically adjusted when in the test mode.
In this overall adjustment mode, the disc is discriminate between
CD and MO, and each adjustment is automatically executed in
order. If a fault is found, the system displays its location. Also,
the manual mode allows each individual adjustment to be auto-
matically adjusted.
• Operation in the test mode is performed with the set. A key
having no particular description in the text, indicates a set key.
• For the LCD display, the LCD on the remote commander is
shown, but the contents of LCD display on the set are same.
Setting Method of Test Mode
There are three different methods to set the test mode:
1
Short SL801 (TEST) on the MAIN board with a solder bridge
(connect pin
<zvn
of IC801 to the ground) and turn on the
[HOLD]
switch. Then, turn on the power.