background image

1-1

MVS-8000SF

Section 1

Installation

1-1. Operating Environment

Operating guaranteed temperature :

+

d

C to 

+

40 

d

C

Performance guaranteed temperature :

+

10 

d

C to 

+

35 

d

C

Operating humidity :

10 % to 90 %
(relative humidity)

Storage temperature :

_

20 

d

C to 

+

60 

d

C

Mass :

Approx. 45 kg
(when all options
are installed)

Prohibited locations for installation

.

Areas where the unit will be exposed do direct sunlight
or any other strong lights.

.

Dusty areas

.

Areas subject to vibration.

.

Areas with strong electric or magnetic fields.

.

Areas near heat sources.

.

Areas subject to electrical noise.

.

Areas subject where is subjected to static electricity.

Ventilation

The inside of the MVS8000SF-C is cooled by a fan (on
both sides).
The power supply can be damaged if the exhaust vent (on
both sides) and air intake (front panel) are blocked or the
fan is stopped.
Therefore, leave a blank space of more than 10 cm in the
front and back of the MVS8000SF-C.

1-2. Power Supply

1-2-1. Power Specifications

A switching regulator is used for the power supply of this
unit. The voltage within the range of 100 V to 240 V can
be used without changing the supply voltage.

Power requirements :

AC 100 to 240 V 

±

10 %

Power frequency :

50/60 Hz

Current consumption : 100 V : 10 A,  240 V : 4.2 A

(with all options installed)

m
.

As the inrush current at turn-on is a maximum 60 A (at
100 V)/110 A (at 230 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source braker will operate or the unit will
abnormally operate.

.

This system contains the two power supply units as the
standard configuration. A fourth, redundant, power
supply may be installed as an option.
When starting up this system, be sure to turn on the
power of all the power supply units.

1-2-2. Recommended Power Cord

w
.

The power cord is not supplied with the MVS8000SF-C.
Be sure to use the power cord that is applicable to places
in the area.
To avoid a fire or an electric shock, be sure to use the
designated power cord.

.

Do not damage the power cord otherwise a fire or
electric shock may result.

 For customers in the U.S.A. and Canada

1

  Power cord, 125 V  10 A (2.4 m) : 

!

 1-557-377-11

AC inlet

1

 For customers in the all European countries

1

  Power cord, 250 V  10 A (2.4 m) : 

!

 1-782-929-21

1

AC inlet

Summary of Contents for MVS8000SF-C

Page 1: ...Edition Revised 2 HK PSU04 MKS 8110HD MKS 8160HD MKS 8170HD MKS 8210HD MKS 8440HD MKS 8210K1 MVS 8000SF MULTI FORMAT SWITCHER PROCESSOR MKS 8110SD MKS 8160SD MKS 8170SD MKS 8210SD MKS 8440SD MKS 8440K1 MKS 8110M MKS 8160M MKS 8170M MKS 8210M MKS 8440M MKS 8420M ...

Page 2: ...e l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparations indiquées dans le mode d emploi à moins d être qualifié pour en effectuer d autres Pour toute réparation faire appel à une personne compétente uniquement MVS 8000SF Serial No 10001 and Higher MKS 8110HD Serial No 10001 and Higher MKS 8110SD Serial No 10001 and Higher MKS 8110M...

Page 3: ...l air ambient temperature of the rack is within the specified limit of this product 4 Prevention against achieving hazardous condition due to uneven mechanical loading When this product is installed in a rack please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading 5 Install the equipment while taking the operating temperature of the equipment into consi...

Page 4: ......

Page 5: ... 3 1 4 2 Installing the Connector Board 1 6 1 4 3 Installing the HK PSU04 1 7 1 4 4 Upgrade 1 7 1 4 5 Installing the MKS 8420M 1 8 1 5 Rack Mounting 1 9 1 6 Matching Connectors 1 11 1 7 Input Output Signals of Connectors 1 12 1 8 Checks on Completion of Installation 1 14 1 8 1 Description of On board Switches and LEDs 1 14 1 8 2 Checks on the Switch Setting the Number of Power Supply Units 1 57 1 ...

Page 6: ......

Page 7: ...S 8xxx MVE 8000 DCU 8000 CCP 8000 to the MVS 8000 system and to start up the system If this manual is required please contact your local Sony Sales Office Service Center Maintenance Manual Available on request This manual describes the detailed service information If this manual is required please contact your local Sony Sales Office Service Center Contents This manual is organized by following se...

Page 8: ......

Page 9: ...e within the range of 100 V to 240 V can be used without changing the supply voltage Power requirements AC 100 to 240 V 10 Power frequency 50 60 Hz Current consumption 100 V 10 A 240 V 4 2 A with all options installed m As the inrush current at turn on is a maximum 60 A at 100 V 110 A at 230 V the capacity of the AC power source must be commensurate with this load If the capacity of the AC power i...

Page 10: ...2 MVS 8000SF 1 3 Installation Space External dimensions Unit mm 1 3 Installation Space External dimensions 1 3 1 MVS8000SF C 35 7 520 375 61 370 144 5 115 5 115 5 35 279 4 354 8U 37 6 17 5 482 339 465 440 ...

Page 11: ... board _ MKS 8440SD DIO 63 board _ Frame Memory Board Set MY 102 board _ Model name Board Structure Plug in board Connector board MKS 8440M DIO 74 board _ Frame Memory Board Set MY 102 board _ MKS 8210K1 DI 43 board _ 1 M E Upgrade Kit DO 44 board _ MKS 8440K1 DIO 74 board _ Frame Memory Upgrade Kit HK PSU04 _ _ Power Supply Unit 1 4 1 Installing the Plug in Boards Each plug in board of the Multi ...

Page 12: ...safe and remove the front panel to the arrow 3 Remove the six screws and remove the plug in board loose proof assembly Screws with drop safe Front panel Screws with drop safe 4 While the eject levers are opened as shown in the illustration insert the plug in board into the board guide rail B3 x 5 B3 x 5 Extract PWB stopper assembly Eject levers 1 4 Installing the Options ...

Page 13: ...r M E Be sure to insert it into the correct slot without fail The slots into which the MKS 8210HD 8210SD 8210M can be inserted are determined in accordance with the configuration of M Es as shown in the following table Slot M E SLOT 3 to 6 M E 1 SLOT 8 to 11 PGM PST 2 Relation between the slots in which OUT 23 OUT 24 OUT 27 boards MKS 8160HD 8160SD 8160M are installed and OUTPUT is shown below Slo...

Page 14: ...lank panel in a safe place 2 Insert the connector board horizontally level and secure it with the two fixing screws Name of option Name of board Slot on the rear side MKS 8110HD CNI 9 board IN 1 to 17 MKS 8110SD CNI 10 board 18 to 34 MKS 8110M CNI 22 board MKS 8160HD CNO 11 board Insert into the slot on the MKS 8160SD CNO 17B board rear that corresponds to MKS 8160 M CNO 23 board the slot on the f...

Page 15: ...e HK PSU04 marked by the arrow and insert the HK PSU04 into deep end as far as it will go 5 Secure the HK PSU04 with the two screws removed in step 3 6 Attach the power supply cover and the front panel by reversing the installation steps of 1 2 1 4 4 Upgrade The MVS 8000 system can be upgraded by the use of the following upgrade kit Name of upgrade Name of board Slot on the kit front side MKS 8210...

Page 16: ...t installed in slot 7 c Be sure to turn off the POWER switch before starting installation work If installation work is started with the POWER switch left on it may cause electrical shock or damage to printed circuit boards Removal 1 Remove the OUT 23 board from the MVS 8000SF 2 Remove the two screws and washers Remove the bracket K 3 Remove the CPU DK module from the connector of the board 4 Peel ...

Page 17: ...he weight of the equipment it may cause death or injury Be sure to use the specified rack mount kit If not injury may result and the equipment may fall due to insufficient strength After rack mounting be sure to tighten the screws on the rack angle and fix the unit in the rack If the screws on the rack angle are not tightened the unit may slip from the rack and fall causing injury c When mounting ...

Page 18: ...crews B4 x 6 two screws each on the right and left for adjusting the length of the adapter completely the screws that were loosened in step 2 5 Remove the front panel of the equipment Refer to Section 1 4 1 B4 x 6 B4 x 6 Portion of the rail Adapter B4 x 10 B4 x 10 31 75 31 75 1U 4U 8U Unit mm 6 Align the groove of the rack tool at the side of the equipment with the rail and slide the equipment to ...

Page 19: ...0SF REF IN BNC 75 Z Belden 8281 coaxial _ REF OUT cable EXT REMOTE 1 to 4 D sub 9 pin Female D sub 9 pin Male TERMINAL Connector 9 pin Male 1 560 651 00 1 Junction Shell 9 pin 1 561 749 00 GPI D sub 25 pin Female D sub 25 pin Male Connector 25 pin Male 1 560 904 11 1 Junction Shell 25 pin 1 563 377 11 DATA RJ 45 modular jack 2 _ _ CTRL DME 1A 1B 2A 2B MDR 68 pin Female Dedicated cable _ supplied w...

Page 20: ...cted together on the CN 2133 board GPI D sub 25 pin Female INPUT x 8 TTL OUTPUT x 4 relay contacts 30 V 0 1 A resistive load OUTPUT x 4 open collector 30 V rated voltage Pin No Signal Name Function 1 GND Ground 2 GND Ground 3 GPI IN 2 General purpose input 4 GPI IN 4 5 GPI IN 6 6 GPI IN 8 7 GPI OUT 1B General purpose open 8 GPI OUT 2B collector output B 3 9 GPI OUT 3B 10 GPI OUT 4B Pin No Signal N...

Page 21: ... TX_ Transmitted data _ 3 RX Received data 4 GND Common ground 5 _ No Connection 6 GND Common ground 7 TX Transmitted data 8 RX_ Received data _ 9 _ No Connection 5 DEVICE Controlling equipment DATA CTRL 100BASE TX RJ 45 8 pin Pin No Signal Name Function 1 TX Transmitted data 2 TX_ Transmitted data _ 3 RX Received data 4 _ No Connection 5 _ No Connection 6 RX_ Received data _ 7 _ No Connection 8 _...

Page 22: ...P502 TP503 TP504 D701 D702 D703 D704 TP701 TP702 TP703 TP704 D1003 D1002 D1013 D901 D902 D1032 D1033 S101 S501 S701 S102 S103 S104 S502 S702 S302 S301 S303 CN103 CN503 CN703 CN1002 CN1003 E1 E4 E5 E2 E3 TP1031 TP1002 TP1003 TP1001 G F E D C B A 6 5 4 3 2 1 D12 D18 D19 D10 D13 D14 D15 D16 D17 SW2 SW1 F E D C B A 1 2 3 4 5 DI1 DI4 DI2 DI3 DI6 DI7 DI8 SW1 SW2 F E D C B A 1 2 3 4 5 DI1 DI4 DI2 DI3 DI6...

Page 23: ...for LAN Sets the group ID for connecting LAN For details refer to System Setup Manual S103 A 2 Unit ID setting switch for LAN Sets the unit ID for connecting LAN For details refer to System Setup Manual S104 A 4 Monitor reset switch for the main CPU Pressing this switch resets the system while maintaining this unit through the main CPU control terminal connector S301 A 1 System reset switch Pressi...

Page 24: ...e measuring terminal LED on the CPU DR module Main CPU D10 green A 1 RUN status LED RUN status indication Lit when the CPU DR module starts operating D12 green A 4 CD Card Detect status LED Lit when the CPU DR module is inserted correctly into the parent board D13 green A 1 2 5 V Indicates the statue of the 2 5 V power that is generated by the VCC CORE and supplied to the CPU DR module Lit while t...

Page 25: ...ory All switches are set to OFF for normal operation Default setting when shipped from the factory is all OFF LED on the IF 844 board S BUS D1 B 1 SBUS RX status LED Lit when receiving data Switch on the IF 844 board S BUS S1 B 3 RESET switch Pressing this switch resets the IF 844 board TEST terminal on the IF 844 board E1 B 3 GND terminal Use this terminal as the earth point for measuring the res...

Page 26: ...M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D1 TP2 D5 TP10 D6 TP1 D7 TP3 D9 D8 CN1 S1 E1 E2 E3 E4 E5 TP6 TP7 TP8 TP9 E6 E7 E8 TP4 TP5 TP1000 TP1500 TP2000 TP2500 TP3000 TP3500 TP4000 TP4500 TP6000 TP1001 TP1002 TP1501 TP1502 TP2001 TP2002 TP2501 TP2502 TP3001 TP3002 TP3501 TP3502 TP4001 TP4501 TP6001 TP4002 TP4502 TP6002 DO 41 board A side Component side ...

Page 27: ... 2 3 4 5 6 7 8 9 10 11 12 13 D1 TP2 D6 TP1 D7 TP3 D9 D8 CN1 S1 E1 E2 E3 E4 E5 TP6 TP7 TP8 TP9 E7 TP4 TP5 TP1000 TP1500 TP2000 TP2500 TP3000 TP3500 TP4000 TP4500 TP6000 TP1001 TP1002 TP1501 TP1502 TP2001 TP2002 TP2501 TP2502 TP3001 TP3002 TP3501 TP3502 TP4001 TP6001 TP4002 TP6002 E6 D8 A 6 CONF2 status LED D10 to L10 FPGA Spartan II CONFIG DONE status indication Not lit when configuration is comple...

Page 28: ... 13 FLOE field odd even signal check terminal Used when checking the FLOE signal supplied from the mother board TP10 A 4 5 V check terminal DO 41 board 5 V measuring terminal TP1000 E 9 TP1500 F 9 TP2000 G 9 TP2500 J 9 TP3000 K 9 TP3500 M 9 TP4000 K 4 TP4500 J 4 TP6000 H 4 PLL LOCK signal check terminal DO 41 board PLL LOCK signal measuring terminal TP1001 C 10 TP1501 E 10 TP2001 F 10 TP2501 H 10 ...

Page 29: ... 44 board A side Component side A B C D E F G H J K L M N P R D1 D9504 D9004 TP9001 D5 E8 CN1 S2 S1 E2 E3 E7 E6 TP4 E1 E4 E5 TP5 TP8 TP9 TP9501 TP1 1 2 3 4 5 6 7 8 9 10 11 12 13 Switch S1 A 9 Reset switch Pressing this switch initializes the DO 44 board S2 A 8 JTAG switch Used only for production in the assembly factory Set this switch to ON only when writing program in the JTAG device with ISP Co...

Page 30: ...P9 N 13 CK clock for video signal signal check terminal Used when checking the clock for video signal TP8 M 13 HD horizontal sync signal check terminal Used when checking the HD signal supplied from the mother board TP9001 A 4 1 8 V check terminal 1 8 V measuring terminal TP9501 A 4 3 3 V check terminal 3 3 V measuring terminal ...

Page 31: ...n Not lit when configuration is completed D2 A 9 MIXER C status LED MIXER C CONFIG DONE status indication Not lit when configuration is completed D2201 A 9 TBC A system status LED TBC A system CONFIG DONE status indication Not lit when configuration is completed 3 MIX 45 board MKS 8210HD SD M D2202 A 10 TBC B system status LED TBC B system CONFIG DONE status indication Not lit when configuration i...

Page 32: ...heck the FLOE signal from the mother board TP3602 N 13 HD horizontal sync signal check terminal Use this terminal to check the HD signal supplied from mother board TP3603 N 12 CKX control timing signal check terminal Use this terminal to check the CKX signal supplied from mother board TP3604 N 12 VD vertical sync signal check terminal Use this terminal to check the VD signal supplied from mother b...

Page 33: ...ion Lit when the 3 3 V power is supplied D6061 A 6 D6062 A 5 D6063 A 5 1 8 V 1 8 V power supply status indication Lit when the 1 8 V power is supplied D6065 A 5 12 V 12 V power supply status indication Lit when the 12 V power is supplied If this LED does not light the fuse may have blown 4 KPC 16 board MKS 8210HD SD M D6100 A 10 COMMON WASH FPGA CONFIG DONE status LED COMMON WASH FPGA CONFIG DONE ...

Page 34: ...on in the assembly factory Used for program writing into the JTAG device with ISP TEST terminal E6062 N 12 E6063 N 7 E6064 N 1 E6065 K 10 E6066 K 4 E6069 E 4 GND terminal Use this terminal as the earth point for measuring the respective check terminals TP6000 P 8 SYS_CLK signal check terminal Used for checking the SYSTEM CLOCK signal TP6060 A 2 3 3 V check terminal 3 3 V measuring terminal TP6061 ...

Page 35: ...02 TP4005 TP4004 TP4001 TP4003 TP4000 TP4507 TP4506 TP4502 TP4505 TP4504 TP4501 TP4503 TP4500 TP5007 TP5006 TP5002 TP5005 TP5004 TP5001 TP5003 TP5000 TP5507 TP5506 TP5502 TP5505 TP5504 TP5501 TP5503 TP5500 TP2000 TP2003 TP2001 TP2004 TP2005 TP2002 TP2500 TP2503 TP2501 TP2504 TP2505 TP2502 TP6000 TP6003 TP6001 TP6004 TP6005 TP6002 TP1000 TP1003 TP1001 TP1004 TP1005 TP1002 TP1006 TP1007 TP1500 TP150...

Page 36: ...en the 3 3 V power is supplied D3 A 4 2 5 V 2 5 V power supply status indication Lit when the 2 5 V power is supplied D5 A 5 CONF1 status LED H2 to L2 FPGA Spartan II CONFIG DONE status indication Not lit when configuration is completed D6 A 5 CONF2 status LED D10 to L10 FPGA Spartan II CONFIG DONE status indication Not lit when configuration is completed Switch S1 A 6 DI reset switch Pressing thi...

Page 37: ...8 TP2503 B 8 TP3003 D 5 TP3503 E 4 TP4003 H 5 TP4503 K 5 TP5003 L 5 TP5503 N 5 TP6003 L 8 TP6503 K 8 TP7003 G 8 TP7503 H 8 TP8003 G 4 FRAME signal check terminal DI 40 board FRAME signal measuring terminal TP1004 D 8 TP1504 E 8 TP2004 A 8 TP2504 B 8 TP3004 D 5 TP3504 E 4 TP4004 H 5 TP4504 K 5 TP5004 L 5 TP5504 N 5 TP6004 L 8 TP6504 K 8 TP7004 G 8 TP7504 H 8 TP8004 G 4 CRC signal check terminal DI ...

Page 38: ...d D9051 A 5 1 8 V 1 8 V power supply status indication Lit when the 1 8 V power is supplied D9551 A 4 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power is supplied Switch S1 A 7 DI reset switch Pressing this switch initializes the DI 43 board S101 A 8 JTAG switch Used only for production in the assembly factory Set this switch to ON only when writing program in the JTAG device wi...

Page 39: ...HD signal measuring terminal TP1001 D 8 TP1501 E 8 TP2001 A 8 TP2501 C 8 TP3001 D 5 TP3501 F 5 TP4001 H 5 TP4501 K 5 TP5001 L 5 TP5501 N 5 TP6001 L 8 TP6501 K 8 TP7001 G 8 TP7501 H 8 TP8001 G 5 ERR check terminal SDI signal error measuring terminal TP9001 A 5 1 8 V check terminal 1 8 V measuring terminal TP9501 A 4 3 3 V check terminal 3 3 V measuring terminal ...

Page 40: ...1 1 2 3 4 5 6 7 8 9 10 11 12 13 D3404 S2300 S2301 CN2301 CN2700 E2300 TP2301 E3410 TP1300 TP1303 TP1302 TP1305 TP1301 TP1304 E3427 TP3304 TP3305 TP3306 TP3307 E3404 E3407 E3412 E3417 E3419 E3425 E3426 E3429 E3421 E3411 E3408 TP3300 TP3301 TP3302 TP3303 TP1500 TP3309 TP3308 D3402 D3401 D3400 1 2 3 4 5 DI1 DI4 SW1 SW2 A B C D E F DI8 DI7 DI6 DI3 DI2 CPU DK Module DIF 119 board A side Component side ...

Page 41: ...hen configuration is completed D2701 B 7 D2702 B 6 D2703 B 6 MAIN CPU status LED Main CPU status indication D2800 B 6 XPT status LED XPT CONFIG DONE status indication Not lit when configuration is completed D3100 B 6 TBC 2 system status LED TBC 2 system CONFIG DONE status indication Not lit when configuration is completed D3400 A 5 1 8 V 1 8 V power supply status indication Lit when the 1 8 V powe...

Page 42: ...2300 A 9 RESET switch Pressing this switch resets the DIF 119 and 122 board S2301 A 5 MONITOR reset switch The reset switch that is used to reset the monitor in the maintenance from the TERMINAL Connector CN2301 A 6 TERMINAL pin This pin is connected to the CPU control terminal and used during maintenance Conforms to RS 232C CN2700 A 6 ISP common connector Used only for production in the assembly ...

Page 43: ...nal TP3305 K 11 HDO signal check terminal DIF 122 board HDO signal measuring terminal TP3306 K 12 FLOEO signal check terminal DIF 122 board FLOEO signal measuring terminal TP3307 K 12 CKXO signal check terminal DIF 122 board CKXO signal measuring terminal TP3308 K 12 CK27 signal check terminal DIF 122 board CK27 signal measuring terminal TP3310 H 4 CK1 signal check terminal DIF 122 board Used to c...

Page 44: ...plied D3703 A 4 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power is supplied Switch S2300 A 9 RESET switch Pressing this switch resets the DIF 141 board S2301 A 5 MONITOR reset switch The reset switch that is used to reset the monitor in the maintenance from the TERMINAL DIF 141 board A side Component side A B C D E F G H J K L M N P R D2703 D2702 D2701 D2700 S2700 1 2 3 4 5 6 7...

Page 45: ...nance Conforms to RS 232C CN2700 A 6 ISP common connector Used only for production in the assembly factory Used for program writing into the JTAG device with ISP TEST terminal E2300 B 8 E3404 P 13 E3407 N 8 E3408 L 11 E3410 G 13 E3411 P 1 E3412 N 5 E3414 L 2 E3417 K 5 E3419 E 7 E3421 B 13 E3425 E 3 E3426 D 5 E3427 K 12 E3429 B 5 GND terminal Use this terminal as the earth point for measuring the r...

Page 46: ...V D3 A 5 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power is supplied D4 A 6 2 5 V 2 5 V power supply status indication Lit when the 2 5 V power is supplied D2 A 5 12 V 12 V power supply status indication Lit when the 12 V power is supplied Switch S3401 A 8 XPT RESET switch Pressing this switch initializes the CPU on the XPT 21 board S3301 A 10 MONITOR switch Factory use only Do...

Page 47: ...asuring terminal TP3001 M 12 VCLK signal check terminal VCLK signal measuring terminal TP3002 L 13 VD vertical sync signal check terminal VD signal measuring terminal TP3003 L 13 HD horizontal sync signal check terminal HD signal measuring terminal TP3004 L 13 FLOE Field Odd Even signal check terminal FLOE signal measuring terminal TP3005 L 13 CKX control timing signal check terminal CKX signal me...

Page 48: ...TP605 TP602 TP606 TP1006 TP1106 TP1206 TP1306 TP706 TP806 TP906 TP1003 TP1004 TP1000 TP1001 TP1005 TP1002 E102 E103 TP206 TP207 E104 TP205 E105 E107 D104 D105 D1400 D1401 CN1400 CN1502 D503 D502 D501 TP501 TP607 TP608 TP1007 TP1107 TP1207 TP1307 TP1008 TP1108 TP1208 TP1308 TP707 TP708 TP807 TP808 TP907 TP908 TP502 1 2 3 4 5 DI1 DI4 SW1 SW2 A B C D E F D8 D7 D6 D3 D2 CPU DK Module OUT 23 board A si...

Page 49: ...P800 TP601 TP1000 TP1100 TP1200 TP1300 TP1001 TP1101 TP1201 TP1301 TP701 TP801 TP901 TP204 E101 E108 E107 D104 D105 D1400 D1401 CN1400 CN1502 D503 D502 D501 TP502 TP501 TP602 TP1002 TP1102 TP1202 TP1302 TP702 TP802 TP902 1 2 3 4 5 DI1 DI4 SW1 SW2 A B C D E F D8 D7 D6 D3 D2 CPU DK Module OUT 24 board A side Component side D106 A 4 2 5 V 2 5 V power supply status indication Lit when the 2 5 V power ...

Page 50: ...erminal VD signal measuring terminal TP202 P 12 CKX control timing signal check terminal CKX signal measuring terminal TP203 N 12 HD horizontal sync signal check terminal OUT 23 board HD signal measuring terminal TP204 N 13 FLOE field odd even signal check terminal FLOE signal measuring terminal TP203 P 12 HD horizontal sync signal check terminal OUT 24 board HD signal measuring terminal TP204 P 1...

Page 51: ... measuring terminal TP602 P 10 TP702 L 10 TP802 J 10 TP902 G 10 TP1002 N 4 TP1102 L 4 TP1202 J 4 TP1302 F 4 EAV_Y signal check terminal OUT 24 board EAV_Y signal measuring terminal TP608 N 10 TP708 L 10 TP808 J 10 TP908 G 10 TP1008 N 3 TP1108 L 3 TP1208 J 4 TP1308 F 4 EAV_C signal check terminal OUT 23 board EAV_C signal measuring terminal TP600 M 12 TP601 M 8 TP700 K 11 TP701 K 8 TP800 H 12 TP801...

Page 52: ... TP9501 D1600 E4 TP201 TP205 E7 E6 TP202 TP203 TP204 E2 E5 E3 D9504 TP9001 S1600 E1 CN1400 CN1902 D702 D701 D700 TP2100 TP700 TP702 TP701 TP1200 TP1300 TP1400 TP1500 TP800 TP900 TP1000 TP1100 1 2 3 4 5 DI1 DI4 SW1 SW2 A B C D E F D8 D7 D6 D3 D2 CPU DK Module 1 2 3 4 5 6 7 8 9 10 11 12 1 8 Checks on Completion of Installation The CPU DK module is installed only in the OUT 27 board of slot 14 OUT 27...

Page 53: ...al check terminal FLOE signal measuring terminal TP205 J 12 TP206 J 7 CK clock for video signal check terminal Uses this terminal when checking the clock signal for video TP700 N 3 CPU_CS2 signal check terminal CPU_CS2 signal measuring terminal TP701 M 5 CPU_OE signal check terminal CPU_OE signal measuring terminal TP702 M 5 CPU_WE signal check terminal CPU_WE signal measuring terminal TP800 L 11 ...

Page 54: ...6 TP100 TP3 TP2 D7 D100 D101 D5 S1 TP4 TP5 TP6 TP7 TP8 TP9 TP10 TP1007 TP1006 TP1002 TP1005 TP1004 TP1001 TP1503 TP1000 TP1507 TP1506 TP1502 TP1505 TP1504 TP1501 TP1503 TP1500 TP2000 TP4000 TP2500 TP4500 TP3000 TP5000 TP3500 TP5500 TP2001 TP2002 TP2501 TP2502 TP3001 TP3002 TP3501 TP3502 TP4001 TP4002 TP4501 TP4502 TP5001 TP5002 TP5501 TP5502 E6 E7 E5 E4 E1 E2 E3 DIO 62 board A side Component side ...

Page 55: ... E6 D101 D6 S1 TP4 TP5 TP6 TP7 TP8 TP9 TP10 E7 E5 E4 E1 TP3501 TP3502 E2 E3 CN1 TP1000 TP1500 TP2000 TP4000 TP2500 TP3000 TP3500 TP4500 TP5000 TP5500 TP1001 TP1501 TP2001 TP2501 TP2502 TP2002 TP4001 TP4002 TP4501 TP4502 TP5001 TP5501 TP5502 TP5002 TP3001 TP3002 DIO 63 board A side Component side D100 A 5 CONF1 H2 to L2 FPGA Spartan II CONFIG DONE status indication Not lit when configuration is com...

Page 56: ...al DIO 63 board VD signal measuring terminal TP8 L 12 CKX control timing signal check terminal DIO 63 board CKX signal measuring terminal TP9 L 12 HD horizontal sync signal check terminal DIO 63 board HD signal measuring terminal TP10 L 12 FLOE field odd even signal check terminal DIO 63 board FLOE signal measuring terminal TP100 A 4 5 V check terminal DIO 62 board 5 V measuring terminal TP3 A 5 2...

Page 57: ...TP3500 M 2 TP4000 G 7 TP4500 J 7 TP5000 K 7 TP5500 M 7 VCO_FRQ signal check terminal DIO 63 board VCO_FRQ signal measuring terminal TP1001 E 9 TP1501 G 9 TP2001 H 5 TP2501 J 5 TP3001 L 5 TP3501 N 9 TP4001 H 10 TP4501 K 10 TP5001 L 10 TP5501 N 9 EAV_Y signal check terminal DIO 63 board EAV_Y signal measuring terminal TP2002 H 5 TP2502 J 5 TP3002 L 5 TP3502 N 4 TP4002 H 10 TP4502 J 10 TP5002 L 10 TP...

Page 58: ...ed CN601 A B C D E F G H J K L M N P R 1 2 3 4 5 6 7 8 9 10 11 12 13 D501 D1 D2 TP9001 TP9501 TP1 E6 D3 S601 S1 TP102 TP103 TP104 E7 TP201 TP202 TP203 TP204 E5 E4 E1 E2 E3 TP101 TP1001 TP1501 DIO 74 board A side Component side Switch S1 A 9 DIO reset switch Pressing this switch initializes the CPU on the DIO 74 board S601 A 8 JTAG switch Used only for production in the assembly factory Set this sw...

Page 59: ... video TP201 L 12 VD vertical sync signal check terminal VD signal measuring terminal TP202 L 12 CKX control timing signal check terminal CKX signal measuring terminal TP203 L 12 HD horizontal sync signal check terminal HD signal measuring terminal TP204 L 12 FLOE field odd even signal check terminal FLOE signal measuring terminal TP9001 A 4 1 8 V check terminal 1 8 V measuring terminal TP9501 A 4...

Page 60: ...1 S202 D201 D202 D203 S201 CN12 CN14 E121 E124 E132 E131 TP706 TP705 TP704 TP904 TP905 TP906 E123 TP203 TP204 E122 E129 E508 TP504 TP507 TP505 TP506 E601 E801 E1001 E130 G F E D C B A 6 5 4 3 2 1 D12 D18 D19 D10 D13 D14 D15 D16 D17 SW2 SW1 CPU DR Module A side Component side Switch S201 A 5 MY CPU reset switch Pressing this switch initializes the CPU on the MY 102 board S202 A 5 MONITOR reset swit...

Page 61: ... measuring terminal TP504 F 2 CKX control timing signal check terminal CKX signal measuring terminal TP505 E 12 TP706 L 4 TP906 L 8 FLOE field odd even signal check terminal FLOE signal measuring terminal TP506 E 12 TP704 L 4 TP904 K 8 VD vertical sync signal check terminal VD signal measuring terminal TP507 F 12 TP705 K 4 TP905 K 8 HD horizontal sync signal check terminal HD signal measuring term...

Page 62: ...he 12 V power is supplied If this LED does not light on the fuse may have blown D101 A 3 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power is supplied D102 A 4 1 8 V 1 1 8 V 1 power supply status indication Lit when the 1 8 V 1 power is supplied D103 A 4 1 8 V 2 1 8 V 2 power supply status indication Lit when the 1 8 V 2 power is supplied D803 D804 D805 A 10 CC CPU status LED Ind...

Page 63: ...itch on the CPU DR module C11 Refer to Switch on the CPU DR module in 1 CA 44 Board Switch S2001 A 5 JTAG switch Used only for production in the assembly factory Set this switch to ON only when writing program in the JTAG device with ISP S101 A 8 CC CPU reset switch Pressing this switch initializes the CPU on the CC 90 board S400 A 8 Monitor reset switch The reset switch that is used to reset the ...

Page 64: ...301 S1401 J 3 S1501 S1601 K 3 S1701 L 3 Output band width compensation switch They are the output band width compensation ON OFF switches Use these switches in the factory setting positions Factory setting S101 to S1701 All OFF S101 S301 S201 S401 S501 S601 S801 S901 S1101 S1001 S1201 S1301 S1401 S1501 S1601 S1701 1 2 3 4 A B C D E F G H J K L S701 1 8 Checks on Completion of Installation ...

Page 65: ...lowing position default setting S303 B 1 CA 44 board Switch setting the number of power supply units DIP type S303 1 OFF S303 2 OFF S303 3 ON S303 4 OFF 1 2 3 A B IF 844 S BUS A B 1 2 SG 272 1 2 3 4 5 A B C D E S303 CPU DR Module MAIN CPU CPU DK Module COM CPU 1 CPU DK Module COM CPU 2 G F E D C B A 6 5 4 3 2 1 F E D C B A 1 2 3 4 5 F E D C B A 1 2 3 4 5 1 8 Checks on Completion of Installation ...

Page 66: ... Control Unit MKS 8010 BKS R series HDS X series Device Control Unit Pack DCU 8000 Audio mixer Crossover cable BNC cable a Connect each LAN CTRL DATA to the separate Ethernet switches respectively However a single Ethernet switch can be used for connecting each LAN b Terminate the system with the 75 Z terminators supplied The 75 Z terminators are supplied with the equipment 1 9 System Connection 1...

Page 67: ...upplied with this unit 2 Flow of Video Signals SWITCHER B SWITCHER A c c DME 1B DME 1A b a b b b Switcher Processor Pack MVS8000SF C VTR Reference video signal Reference video signal PRIMARY INPUTS 1 to 34 Camera VTR Routing Switcher 68 pin Cable AC100 to 240 V Power Supply AC100 to 240 V Power Supply AC100 to 240 V Power Supply AC100 to 240 V Power Supply AC100 to 240 V Power Supply MONITOR Video...

Page 68: ......

Page 69: ...ive Connect it correctly YES NO NO YES A picture is not displayed on the monitor screen even though the main power of the MVS 8000SF is turned on Are the standard boards installed into the specified slots Install the standard boards into the specified slots Refer to MVS 8000SF Maintenance Manual Are the option boards installed into the specified slots Are the input and output cables connected corr...

Page 70: ... the main power of the MVS 8000SF turned on for one hour or longer in order to charge the large capacitor The data can be backed up for about one week when the capacitor is fully charged under the normal operating temperature 2 2 Periodic Inspection and Maintenance 2 3 About the Data Backup Capacitor 2 2 Periodic Inspection and Maintenance 2 2 1 Cleaning 1 Front panel The filter on the rear of the...

Page 71: ...é de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrücklich...

Page 72: ...Printed in Japan Sony Corporation 2003 3 16 B P Company 2002 MVS8000SF C SY E 3 620 565 03 ...

Reviews: