Specifications
Model
MT10/MT11
Item
Connected scale unit
DT12N/DT12P
Resolution
5
µ
m
Maximum response speed
60 m/min
Maximum response acceleration
2400 m/s
2
Cable length
0.3 m/0.98 ft
Power voltage
DC5 V
±
4%
Power consumption
0.7 W (MT10),
*
1 W (MT11)
Operating temperature
0 to 50
°
C/32 to 122
°
F
Strage temperature
–10 to 60
°
C/14 to 140
°
F
Mass
About 90 g
Supplied accessories
Instruction manual
Cable color
Signal
Red
Power 5V
White
Power supply 0V
Brown
Power supply 0V
Black
Power supply 0V
Yellow
A
Blue
A
Gray
B
Orange
B
Purple
ALARM
Green
ALARM
Shield
FG
L
MT11 cable color
L
MT11 output specifications
Output signal
: A/B phase, Alarm
Output format
: Differential line driver (equivalent to EIA-422)
Phase A/Phase B phase difference
: Changes as follows according to the travelling velocity of the scale unit.
(Sampling is performed every 120
µ
s.)
Travelling velocity : v [m/min]
Phase difference : T [
µ
s]
0
<
v
<
12.5
20.0
12.5
≦
v
<
32.5
8.8
32.5
≦
v
≦
60.0
4.5
Alarm signal : This signal is output when the response acceleration is
exceeded or when a scale unit is not connected. The minimum
output pulse width is 10 ms, and the alarm output signal also
recovers automatically when the alarm status is canceled.
L
Optional Accessories
Extension cable
(These are extension cables for use between scale unit and the detector.)
CE08-1 (1 m)
CE08-3 (3 m)
CE08-5 (5 m)
CE08-10 (10 m)
CE08-15 (15 m)
Specifications and appearances of the products are subject to change without notice because of improvement.
•
Power supply 0V (white, brown and black) and
the shield are connected with a capacitor.
(isolated with respect to DC)
*
The power consumption of 1 W marked with
MT11 stands for the output to a differential output
load of 120
Z
.