1-9 (E)
MPE-200
2. KY-660 board
<Switch >
Ref No.
Address
Name
Function
Factory setting
S102
(A-2)
_
S102-1: Bank switching of NOR flash memory
All OFF
ON: Backup
OFF: Main
S102-2: Sets the starting mode.
ON: Automatically starts when the AC
power turns on.
OFF: Does not start automatically.
S102-3: Sets the starting path.
ON: Forcibly starts in the maintenance mode.
OFF: Starts with the path set on the firmware.
S102-4 to 6: Not used
S102-7, 8: Sets the RS-232C function
*
1
*
1: Setting the RS-232C function
S102-7
S102-8
Front side RS-232C
*
*
*
*
*
2
Rear side RS-232C
OFF
OFF
Not used
Console/System control mode
ON
OFF
Console mode
System control mode
OFF
ON
Console/System control mode
Not used
ON
ON
Not used
Not used
*
2: The RS-232C connector of the front side is on the KY-660 board. When using it, the front panel must be removed.
(For the procedure to remove the front panel, refer to “2-2-1. Cleaning”.)
1
2
3
4
5
6
7
8
( indicates the knob position.)
S102
D107
D108
D109
D110
D111
A
B
C
1
2
Side A
CN202
RS-232C
Summary of Contents for MPE-200
Page 4: ......
Page 6: ......
Page 8: ......
Page 24: ......
Page 26: ...Printed in Japan Sony Corporation 2012 4 08 2009 MPE 200 SY J E 4 172 042 02 ...