29
MDS-SE9
Record Bias Adjustment
Procedure :
1. Press the
[FUNCTION]
button to select TAPE. (HCD-SE9)
2. Insert a tape into deck, press the
[TAPE REC]
button, and then
press the
TAPE
X
button to start recording.
3. Mode : Record
4. Mode : Playback
5. Confirm playback the signal recorded in step become adjustment
level as follows
If these levels do not satisfy adjustment level, adjust the RV241
(L-CH) and RV291 (R-CH) on the MAIN board to repeat steps
3 and 4.
Adjustment level : The playback output of 10kHz level difference
against 315Hz reference should be 0
±
3.0dB.
Adjustment Location :
[MAIN BOARD](SIDE B)
AF OSC
1) 315 Hz
2) 10 kHz
blank tape
CS-123
set
attenuator
600
Ω
50 mV (–23.8 dB)
MD/TAPE OUT (J401)
recorded
position
level meter
set
MD/TAPE OUT (J401)
Tape speed Adjust
RV321
RV291
Record Bias Adjust (R-CH)
RV241
Record Bias Adjust (L-CH)
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
Adjustment Location: REC/PB Head
Tape Speed Check
Procedure:
1.
MODE : FWD Playback.
2.
Insert the WS-48B into deck.
3.
Press the
TAPE
Y
button of deck.
4.
Check the reading of frequency counter becomes 3000 ± 90
Hz. If these level do not satisfy adjustment level, adjust the
RV321.
Adjustment Location: MAIN BOARD
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.35%
(test tape: WS-48B)
3.
Mode: Playback
test tape
P-4-A100
(10kHz, –10dB)
oscilloscope
set
Waveform of oscilloscope
in phase
45
°
90
°
135
°
180
°
good
wrong
V
H
R-ch
L-ch
GND
R-CH
MD/TAPE OUT (J401)
L-CH
test tape
WS-48B
(3kHz, 0dB)
frequency
counter
set
MD/TAPE OUT (J401)