5-14
Adjusting method:
1) Install the unit so that the distance between its lens surface
and mini-pattern box is less than 3 cm.
2) Align both heights of unit and mini-pattern box.
3) Make sure that the output voltage of regulated power supply is
11.29 ± 0.01 Vdc.
4) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
5) Select page: 0, address: 01, and set data: 01.
6) Check that the data on page: F, addresses: 14 to 25 are initial
values (See table below).
7) Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjusting remote commander.
8) Select page: 6, address: 01, set data: 27, and press the PAUSE
button of the adjusting remote commander.
(The flange back adjustment is performed and the adjustment
data is stored in page: F, address: 14 to 25)
9) Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
2) Select page: 0, address: 01, and set data: 00.
3) Perform “Flange Back Check”.
Address
Data
Address
Data
FD83 FD88
FD83 FD88
14
22
1C
1D
00
00
15
44
94
1E
35
46
16
31
26
1F
00
00
17
32
EC
20
20
20
18
16
13
21
20
20
19
BA
B9
22
6E
20
1A
00
00
23
44
44
1B
00
00
24
0A
0A
1C
00
00
25
00
00
Fig. 5-1-12
2. Flange Back Adjustment
(Using the mini-pattern box)
The inner focus lens flange back adjustment is carried out auto-
matically.
If disordered, the focus will be deviated during auto/manual fo-
cusing.
Mode
STILL
Subject
Siemens star chart with ND filter
for mini-pattern box (Note 1)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
14 to 25
Note 1:
Siemens star chart used is a darker one.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparation:
Install the mini-pattern box as shown below.
Note:
The attachment lenses are not used.
Mini-pattern box
3 cm or less
Mavica
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
No connection
Regulated power supply
11.29
±
0.01 Vdc, 3.5 A or more
Summary of Contents for Mavica MVC-FD83
Page 8: ...1 1 SECTION 1 GENERAL This section is extracted from instruction manual MVC FD83 FD88 ...
Page 9: ...1 2 ...
Page 10: ...1 3 ...
Page 11: ...1 4 ...
Page 12: ...1 5 ...
Page 13: ...1 6 ...
Page 14: ...1 7 ...
Page 15: ...1 8 ...
Page 16: ...1 9 ...
Page 17: ...1 10 ...
Page 18: ...1 11 ...
Page 19: ...1 12 ...
Page 20: ...1 13 ...
Page 21: ...1 14 ...
Page 22: ...1 15 1 15 E ...
Page 27: ...MVC FD83 FD88 3 1 3 2 3 3 SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM to ...