English
11
3-2. Interface cable
Use a shielded cable with a thickness of ø10 mm or less for the interface cable.
Also, leave the connected device side of the shielded cable open; do not connect it to earth
(GND).
(The shielded cable should be procured separately.)
Note
Be sure to secure the interface cable or take other measures to prevent accidental
disconnection.
Outer cover
Knitted shield
Cross section of the cable
Assembling the supplied plug
1
2
3
3
4
2
4
Cable clamp
Back shell
Cable
Plug
Fold back the braided wire and
secure with the metal clips.
Front shell
1
Fold back the braided wire of the portion to be inserted into the cable plug.
2
Pass the cable through the back shell and solder it to the plug.
3
Insert the plug into the back shell, then fit the front and back shells together so that the
hooks on the front shell are caught in the holes on the sides of the back shell.
4
Tighten the cable clamping screw to secure the cable.
Summary of Contents for LZ60-B1
Page 28: ... Memo ...
Page 29: ... Memo ...