3-2
LMD-1420/1410
Are harness
and flexible flat cable
connected correctly?
Is the symptom
improved when another
J board is installed?
Replace the BA board.
System does not start.
Is the symptom
improved when another
GA board is installed?
Yes
Replace the GA board.
Replace the J board.
No
Yes
No
No
Yes
Connect the harness and
flexible flat cable correctly.
Are harness
and flexible flat cable
connected correctly?
Is the symptom
improved by the external
operation of PARALLEL
REMOTE terminal?
Replace the H board.
Operation of this unit is abnormal.
Yes
Replace the BA board.
No
Yes
No
Connect the harness and
flexible flat cable correctly.
n
For the external operation of PARALLEL REMOTE terminal,
refer to the Operating Instructions.
3-2. System does not start
3-3. Operation of this unit is abnormal